dormakaba RTS88 Package 31 Installation Instructions
08279291
02-2020
RTS88 Closers
5
Adjustments - closing speeds
8511 applied stop
2
Adjustments
2.1.1
Valve “A” - controls closing speed from
maximum opening angle to 0°.
•
Clockwise - decreases closing speed
•
Counter-clockwise - increases closing speed
2.1.2
Valve “B” - increases closing speed from
maximum openig angle to 20°.
Counter-clockwise - increases closing speed.
Valve “B”
“A”
“B”
Valve “A”
2.1 Adjust closing speeds
Fig.3
2.2 Optional 8511 applied stop (or stop by others)
Fig.4
2.1.1
Prepare header according to template above.
2.1.2
Install applied stop as shown in Fig 2. with
three No.10-32 flat head machine screws.
1”
[25]
1”
[25]
1/8”
[3]
2”
[51]
Clearance
Front view
Bottom view
Cutout in stop
For 10-32 machine screws use No.21
drill and tap
One hole in cover plate
Two holes in frame
8511 applied stop
1-1/4”
[32]
7/8”
[22]
14-1/4”
[362]
1/2”
[13]
17-1/2”
[445]
35”
[889]
Side view