Introduction 

This document outlines how to set up a 700 series lock to use the Remote Disable 
function. 

About Remote Disable 

A configurable Input Signal is available on systems using 702, 703, 704, and 705 Keypad 

models. Using the Input Signal will require the installation of a Battery/Alarm Box 

(Item/Order # 704045).  

 

Note: 

While not configurable for 701 locks, they do have an input signal that controls 

this Remote Disabled/Lockout function.  

 

When used in a multi-lock system, Lock #1 monitors the state of this signal, and 

depending on how it is configured, it will perform one of the following functions when 

this signal is asserted:  

 

Ignored 

- Input Signal will have no effect on how the system operates  

 

Remote Disabled/Lockout 

- When an open lock request is received for any lock, 

all requests to open will be blocked regardless of which target lock the user is 

attempting to open. This is the default setting.  

 

Time Delay Override 

- Time Delay for all locks in the system is cancelled and any 

lock may be opened immediately by a user. If one or more locks were in either the 

Delay Period or the Confirmation Window, Time Delay is canceled, and the lock 

can be opened immediately by a user, with open privilege, providing the correct 

credentials  

 

Dual User Override 

- Dual User requirements are ignored, allowing a single user 

to open a lock or access the menus  

 

With the application of the Alarm Box, the opening sequence can be disabled by 

asserting a signal on the Alarm Box. The signal may come from an external alarming 

system that could be connected to this lock to prevent it from opening.  

 

Please observe the following while using the Remote Disable:  

 

The Remote Disable assertion will not block users from accessing the menus on a 

Display Keypad  

 

The signal must be asserted prior to the user authentication for it to be 

recognized by the system  

 

Duress combinations will still trigger the alarm signal, even if Remote Disable is 

asserted  

 

A Keypad with a display will show ‘Lock #x NOT open’ when the Remove Disable 

is asserted. The ‘x’ would be replaced by a lock that is targeted to be opened  

Содержание Remote Disable

Страница 1: ...able of Contents Introduction 2 About Remote Disable 2 Remote Disable LA GARD Software Setup 3 Remote Disable Keypad Setup 5 Display Keypad Setup 5 Non Display Keypad Setup 6 Alarm Box Input Signal Overview 6 Connecting the Input Signal 6 Mount the Alarm Box 6 Connect the Alarm Box 6 Alarm Box Connection Diagram 7 ...

Страница 2: ...ime Delay Override Time Delay for all locks in the system is cancelled and any lock may be opened immediately by a user If one or more locks were in either the Delay Period or the Confirmation Window Time Delay is canceled and the lock can be opened immediately by a user with open privilege providing the correct credentials Dual User Override Dual User requirements are ignored allowing a single us...

Страница 3: ...se your Systems list will appear blank If this is the case create a new System by clicking the Create icon 4 If creating a new System enter a System name in the space provided and configure all other fields settings based on your preferences For more information about LA GARD software and 700 series system settings please refer to the System User Guide Document 7040 1121 and the help menu included...

Страница 4: ... the USB Port of the PC b Plug the USB connector end of the cable into the dongle c Plug the mini USB end of the cable into the mini USB port on the Keypad 9 On the Keypad enter a valid User ID and the corresponding combination the same ID and combination used in step 6 10 Using the arrow buttons on the Keypad navigate through the Main Menu and select PC Link The LED on the Keypad will illuminate ...

Страница 5: ...splay Keypad Setup Follow these steps to configure the Input Signal on a Display Keypad 1 Enter an Authorized User ID and Combination 2 Navigate through the Main Menu and select System 3 Select Input Signal from the sub menu 4 Scroll through the list of options and select Disable Open to set the Input Signal to Remote Disable mode 5 Success Mode updated will appear on screen and the Keypad will be...

Страница 6: ... Input Signal This section outlines how to connect the Input Signal from your alarm control system to your 700 series Lock and Keypad using the Alarm Box to make use of the Remote Disable function Mount the Alarm Box Mount the Alarm Box to the interior safe wall via the holes and screws provided Connect the Alarm Box For multi lock configurations the silent alarm works only with the primary lock t...

Страница 7: ...Document 7040 0320 for further instructions on how to change silent alarm and remote disable settings Alarm Box Connection Diagram Lock Connector Connect to BAT port on lock with 41040 2 cable 9V DC Connector Optional connection to 701107 AC Power Supply Kit Terminal Block Connection to alarm control panel 1 EXT Control Signal Reference Voltage or Ground 2 EX 5V DC Min to 12V DC Max Control Signal...

Отзывы: