Technical specifications

1.1 Overview

These instructions are for installation of MUTO 
COMFORT sliding door system M50 for the following 
mounting and style versions:

1.  Ceiling mount

1.1.1

 

General information

• 

dormakaba requires use of tempered monolithic or 
tempered laminated glass.

• 

dormakaba glass hardware is not suitable for 
application in rooms where chemicals (e.g. chlorine) 
are used as indoor swimming pools, saunas or 
salt-water pools.

• 

Never move sliding panels faster than walking 
speed and always stop the door manually before it 
reaches end position.

• 

Do not slide doors with excessive force. Install 
limiting stop to prevent door from opening too far.

1.1.2

 

Intended use

• 

For sliding door in dry indoor areas only

• 

For manual slowly opening and closing only

1.1.3

 

Glass requirements and fittings

• 

The substructure/wall must be able to bear 
permanent loads and be level (max. tolerance: 
1/16” [2] per 39” [1m]).

• 

Fasteners must be sufficiently dimensioned for the 
substructure/wall and weight of the door.

• 

When adjusting glass components, always stick to  
the required clearance for the respective  

 

hardware. Adjust clearance so glass does not  
come in contact with any hard surfaces such as  
glass, metal or concrete.

• 

Do not use excessive force when installing the  
glass (avoid over tightening screws).

1.1.4

 

Requirements for glass panel

• 

dormakaba requires use of fully tempered glass, 
which complies with ASTM C 1036 and ASTM C 
1048. Secondary heat soaking processes are 
recommended but not required. This applies to 
both tempered monolithic and tempered laminated 
glass.

• 

Clamping area must be flat and uncoated (no 
self-cleaning coating!)

• 

Never use glass with conchoidal fractures and/or 
damaged edges.

1.1.5

 

Safety instructions

• 

Installation requires two people.

• 

Only properly qualified and specially trained staff 
are authorized to mount dormakaba glass 
hardware.

• 

Due to crushing hazards and possible injury caused 
by breakage of glass during mounting, 
corresponding protective clothing (especially gloves 
and protective goggles) is required.

• 

Never clamp metal fitting hardware directly to 
glass surface.

1.1.6

 

Symbols used - Safety/Installation

CAUTION

Mounting components must meet the 
requirements of substructure/wall and door 
weight. Please read the technical information 
for fittings.

WARNING

Risk of breaking glass. When installing the 
door, support the door panel with a block of 
wood or similar object.

TIPS AND RECOMMENDATIONS

Information note

CLOSING EDGE

1.1.7

 

Maintenance, care, repair

• 

Immediately replace damaged parts.

• 

Always use original dormakaba parts.

• 

Clean clamping area with alcohol-based standard 
commercial cleaning agent before mounting the 
glass hardware.

• 

Use a damp clothe for occasional cleaning, 
especially the track.

• 

Always use silicone - and oil-free cleaners (e.g. 
acetone).

• 

Check glass hardware at regular intervals for 
proper positioning and smooth operation and 
correct adjustment.

• 

High traffic door systems require inspection by 
properly qualified staff (specialized companies or 
installation firms.)

1.1.8

 Disposal

Disposal in accordance with local, state and national 
regulations.

1   Technical specifications

Содержание Muto Comfort M50

Страница 1: ...Muto Comfort M50 Ceiling mount less Dormotion Installation instructions 936021 05 2018 EN ...

Страница 2: ...ir 3 1 1 8 Disposal 3 2 Installation instructions 4 2 1 Overall 4 2 2 Securing track to mounting surface 5 2 3 Door wall dimensions 6 2 4 Specifications technical data 6 2 5 Installing roller carriers on monolithic glass ONLY 7 2 6 Installing end stops 7 2 7 Install glass rollers in track 8 2 8 Engaging anti jump 8 2 9 Install floor guide 9 2 10 Install floor guide continued 9 2 11 Adjustment door...

Страница 3: ...36 and ASTM C 1048 Secondary heat soaking processes are recommended but not required This applies to both tempered monolithic and tempered laminated glass Clamping area must be flat and uncoated no self cleaning coating Never use glass with conchoidal fractures and or damaged edges 1 1 5 Safety instructions Installation requires two people Only properly qualified and specially trained staff are au...

Страница 4: ...ation Instructions MUTO Comfort 05 2018 936021 4 Overall 1 1 Cover 1 2 Brush strip 1 3 Track 1 4 End cap 2 1 Overall 2 Installation instructions 1 5 End stop 1 6 Cover clips 1 7 Roller carrier 1 8 Floor guide 1 1 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 5 1 4 1 7 1 6 ...

Страница 5: ...n the interior of this surface Track mounting screws must fully penetrate the steel angle metal stud or at a minimum of 2 51 into wood blocking utilizing the predrilled holes in the MUTO track Consult with a structural engineer to determine if reinforcement is adequate for your specific application or to meet specific codes in your location 2 2 1 Ensure the track is properly level and secure it to...

Страница 6: ... 1 3 16 30 1 3 16 30 clear opening height CH clear opening width CW Glass door Glass door panel DW 3 8 10 Bottom of glass to floor Back of track to center of mounting hole in track 1 25 Single Door M50 Ceiling mount Door leaf weight lbs kg 110lbs 50 Including weight of auxiliary hardware 2 3 Door wall dimensions 2 4 Specifications technical data ...

Страница 7: ...SS LEADING IS SIDE CLOSEST TO LATCH CLOSED Secure Legend Closing edge of door Hex key size M50 3mm Back of Glass Back of Glass X Z 3 1 8 80 3 1 8 80 Glass gasket Roller carrier 2 5 Installing roller carriers on monolithic glass ONLY Fig 2 2 6 1 Slide end stops into each end of the track NOTE DO NOT FULLY TIGHTEN NOTE Exact location adjustments will be determined in Adjustment End Stop Location ste...

Страница 8: ...ss and rollers upward and rest rollers on track ENSURE ROLLERS AND TRACK ARE FREE OF DEBRIS Setting blocks 2 7 Install glass rollers in track Fig 4 2 8 1 Temporarily engage anti jump on roller carrier 2 8 2 Using appropriate size ball end hex key turn adjustment screw CLOCKWISE to engage anti jump Hex key size M50 2mm Anti jump Anti jump adjustment screw 2 8 Engaging anti jump Fig 5 Rollers ...

Страница 9: ...nto mounting surface using a 5 16 drill bit 2 9 7 Secure floor guide anchor with included fasteners Glass X Floor guide M50 X 1 1 4 T 2 31 5 T 2 Floor guide anchor 1 7 1 6 3 6 1 3 1 6 2 0 Wall T 2 9 Install floor guide Fig 6 2 10 1 SET GLASS AND ROLLERS BACK ONTO TRACK 2 10 2 Slide floor guide over floor guide anchor and tighten with set screws 2 10 3 Remove setting blocks NOTE Be sure glass is ce...

Страница 10: ...ew CLOCKWISE or COUNTER CLOCKWISE to raise or lower glass NOTE Be sure glass is level during this adjustment 2 11 3 Re engage anti jump by turning anti jump adjustment screw CLOCKWISE NOTE Anti jump should NOT touch track Door height adjustment tolerance M50 5 32 4 3 32 2 Glass Floor guide 3 8 10 Hex key size M50 2 5mm Anti jump adjustment screw 0 X 1 32 0 5 X Height adjustment screw 2 11 Adjustme...

Страница 11: ...ller carrier NOTE bi folding Be sure there is a 1 4 6 gap between the right and left hand sets 0mm END STOP LOCATION LEADING EDGE Bumper Edge of roller carrier End stop Door closed Door pull Jamb edge Glass edge max 1 3 16 30 Glass overlap on wall Door pull to jamb distance Verify with local jurisdiction Bumper Secure Bumper Secure Hex key size M50 2mm 2 5mm M50 torque 3 ft lbs 4 Nm Door opened 0m...

Страница 12: ... clips Brush profile 2 13 1 Insert cover clips into track One clip per foot 2 13 2 Insert perpendicular to track and turn CLOCKWISE to snap into place 2 14 1 Measure and cut brush to appropriate length 2 14 2 Slide brush into track Cover clip Brush Track 2 13 Cover clips 2 14 Install brush profile Fig 11 Fig 12 ...

Страница 13: ... Cover End caps 2 15 1 Secure cover to clips and snap into place NOTE Roll cover from the bottom upwards Ensure the bottom of the cover is supported by the groove in the cover clip 2 16 1 Snap end caps onto track End cap End cap Cover 2 15 Install cover 2 16 Install end caps Fig 13 Fig 14 Cover Cover clip ...

Страница 14: ...www dormakaba com dormakaba USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...

Отзывы: