background image

dormakaba MUTO Premium XL150/80/120 / MUTO Comfort L80  
Fixed Panel Installation Instructions

MUTO Premium/Comfort Fixed Panel

05-2018

936020

3

Technical specifications

1   Technical specifications

1.1 Overview

These instructions are for installation of MUTO 
PREMIUM and COMFORT sliding door system 
XL150/80/120 / L80 for the following mounting and 
style versions:

1.  Ceiling mount

1.1.1

 

General information

• 

dormakaba requires use of tempered monolithic or 
tempered laminated glass.

• 

dormakaba glass hardware is not suitable for 
application in rooms where chemicals (e.g. chlorine) 
are used as indoor swimming pools, saunas or 
salt-water pools.

• 

Never move sliding panels faster than walking 
speed and always stop the door manually before it 
reaches end position.

• 

Do not slide doors with excessive force. Install 
limiting stop to prevent door from opening too far.

1.1.2

 

Intended use

• 

For sliding door in dry indoor areas only

• 

For manual slowly opening and closing only

1.1.3

 

Glass requirements and fittings

• 

The substructure/wall must be able to bear 
permanent loads and be level (max. tolerance: 
1/16” [2] per 39” [1m]).

• 

Fasteners must be sufficiently dimensioned for the 
substructure/wall and weight of the door.

• 

When adjusting glass components, always stick to  
the required clearance for the respective  

 

hardware. Adjust clearance so glass does not  
come in contact with any hard surfaces such as  
glass, metal or concrete.

• 

Do not use excessive force when installing the  
glass (avoid over tightening screws).

1.1.4

 

Requirements for glass panel

• 

dormakaba requires use of fully tempered glass, 
which complies with ASTM C 1036 and ASTM C 
1048. Secondary heat soaking processes are 
recommended but not required. This applies to 
both tempered monolithic and tempered laminated 
glass.

• 

Clamping area must be flat and uncoated (no 
self-cleaning coating!)

• 

Never use glass with conchoidal fractures and/or 
damaged edges.

1.1.5

 

Safety instructions

• 

Installation requires two people.

• 

Only properly qualified and specially trained staff 
are authorized to mount dormakaba glass 
hardware.

• 

Due to crushing hazards and possible injury caused 
by breakage of glass during mounting, 
corresponding protective clothing (especially gloves 
and protective goggles) is required.

• 

Never clamp metal fitting hardware directly to 
glass surface.

1.1.6

 

Symbols used - Safety/Installation

CAUTION

Mounting components must meet the 
requirements of substructure/wall and door 
weight. Please read the technical information 
for fittings.

WARNING

Risk of breaking glass. When installing the 
door, support the door panel with a block of 
wood or similar object.

TIPS AND RECOMMENDATIONS

Information note

CLOSING EDGE

1.1.7

 

Maintenance, care, repair

• 

Immediately replace damaged parts.

• 

Always use original dormakaba parts.

• 

Clean clamping area with alcohol-based standard 
commercial cleaning agent before mounting the 
glass hardware.

• 

Use a damp clothe for occasional cleaning, 
especially the track.

• 

Always use silicone - and oil-free cleaners (e.g. 
acetone).

• 

Check glass hardware at regular intervals for 
proper positioning and smooth operation and 
correct adjustment.

• 

High traffic door systems require inspection by 
properly qualified staff (specialized companies or 
installation firms.)

1.1.8

 Disposal

Disposal in accordance with local, state and national 
regulations.

Содержание Muto Comfort L80

Страница 1: ...Muto Premium XL150 80 120 Muto Comfort L80 Fixed Panel ONLY Ceiling mount Installation instructions 936020 05 2018 EN ...

Страница 2: ...bols used Safety Installation 3 1 1 7 Maintenance care repair 3 1 1 8 Disposal 3 1 2 Tempered laminate glass TLG and adhesive specifications 4 2 Installation instructions 5 2 1 Overall 5 2 2 Securing gasket to track 6 2 3 Secure sidelite section profile to track and mounting surface 7 2 4 Door wall dimensions 8 2 5 Installing U channel for sidelite 9 2 6 Installing sidelite glass 9 2 7 Installing ...

Страница 3: ... use of fully tempered glass which complies with ASTM C 1036 and ASTM C 1048 Secondary heat soaking processes are recommended but not required This applies to both tempered monolithic and tempered laminated glass Clamping area must be flat and uncoated no self cleaning coating Never use glass with conchoidal fractures and or damaged edges 1 1 5 Safety instructions Installation requires two people ...

Страница 4: ...esive 3M Scotch Weld EPX Plus II Mixing Square Nozzle 5 3mm 3 934 805 Pk of 4 4 nozzles per 1 tube of adhesive MUTO Accessory set Clamp carrier plate gasket for TLG 807 640 1 set Handling time frame Function Time Working life time between application and clamping of carrier 5 minutes 75 F Handling strength 20 minutes 73 F or more Full cure time ormal door usage not recommended until full cure time...

Страница 5: ... 936020 5 Overall 1 1 Cover 1 2 Track 1 3 End Cap 1 4 Sidelite end cap 1 5 Sidelite section profile 1 6 Cover clips 2 1 Overall 2 Installation instructions 1 7 U channel 1 8 U channel end caps 1 9 View protection clips 1 10 View protection profile 1 11 Sidelite glass gasket 1 1 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 3 1 4 1 10 1 9 1 11 1 8 ...

Страница 6: ...ed Panel 05 2017 936020 6 Sidelite gasket 2 2 Securing gasket to track Fig 1 Sidelite gasket 2 2 1 Ensure track is cut to proper length NOTE SEE DIMENSION INSTRUCTIONS ON PAGE 8 2 2 2 Cut adhesive gasket equal to track length 2 2 3 Adhere gasket along bottom edge of back of track Track Adhesive gasket Sidelite glass ...

Страница 7: ...nting screws must fully penetrate the steel angle metal stud or at a minimum of 2 51 into wood blocking utilizing the predrilled holes in the MUTO track Consult with a structural engineer to determine if reinforcement is adequate for your specific application or to meet specific codes in your location 2 3 1 Align sidelite profile screw slot with track profile holes NOTE Holes will be predrilled ev...

Страница 8: ...ecifications 2 4 Door wall dimensions Sidelite mount XL150 XL80 L80 1 4 6 Sidelite glass FPW Sidelite glass FPW Sidelite mount XL120 1 4 6 Sidelite glass FPW Sidelite glass FPW Back of track to center of mounting hole in track 7 8 23 Back of track to center of mounting hole in track 7 8 23 Bottom of glass to floor 1 2 13 Bottom of glass to floor 1 2 13 ...

Страница 9: ...e setting blocks into u channel 2 6 2 Spray inside of u channel with glass cleaner 2 6 3 Lift glass up and into sidelite profile 2 6 4 Lower glass down into u channel 2 6 5 Ensure there is 1 8 3 gap between wall and edge of sidelite glass NOTE If using tempered laminated glass gently press glass against u channel gasket and dispense silicone along full length of non gasket side of u channel NOTE I...

Страница 10: ... 7 2 Press gasket in between sidelite glass and sidelite profile Sidelite gasket Sidelite gasket location Sidelite profile Sidelite glass 2 7 Installing sidelite glass gasket Fig 5 Sidelite gasket 2 8 Install cover clips 2 8 1 Insert cover clips into track 2 8 2 Insert perpendicular to track and turn CLOCKWISE to snap into place NOTE 1 clip per foot of cover extrusion Fig 6 Cover clips Cover clip ...

Страница 11: ...lip per foot of profile Exception If profile is minimum of 1 foot in length use 2 clips View protection profile Sidelite glass View protection clip TO BE USED WITH ONE OR MULTIPLE SIDELITE APPLICATIONS Cover View protection clips 2 9 Install view protection clips Fig 7 View protection clips Sidelite glass 2 10 1 Tip cover spacers into outter most edge of track 2 10 2 Place one at each end of track...

Страница 12: ... Cover end caps Sidelite profile end caps U channel end caps 2 11 Install cover and view protection profile Fig 9 Cover and profile 2 11 1 Secure cover to clips and snap into place NOTE Roll cover from the bottom upwards Ensure the bottom of the cover is supported by the groove in the cover clip 2 11 1 Once cover is in place tip view protection profile up in between track and cover 2 11 2 Snap dow...

Страница 13: ...www dormakaba com dormakaba DORMA USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...

Отзывы: