dormakaba 8900 T/TH Installation Instructions
08280121
09-2019
8900 Surface Applied Closers
6
Adjust closing speeds
Adjust hold open
3
Adjustments
Confirm closer spring size prior to making any
closing speed adjustments.
Do not back valve heads out beyond closer casting.
Door should close in 3 to 6 seconds from 90º.
Maximum opening angle is 80° - 160º.
Do not close valves completely.
3.1 Adjust closing speeds: sweep, latch, backcheck, delayed action
Fig.5
Increase
Decrease
Increase
Decrease
Backcheck &
Delayed Action
Sweep & Latch
3.1.1 Adjust
closing sweep speed
: 90° to start of latch speed.
•
Increase sweep speed: Turn valve counter-clockwise
•
Decrease sweep speed: Turn valve clockwise.
3.1.2 Adjust
closing latch speed:
15° to close.
•
Increase latch speed: Turn valve counter-clockwise
3.1.3 Adjust
opening backcheck:
beginning at 70°.
•
Increase resistance: Turn valve clockwise
•
Decrease resistance: Turn valve counter-clockwise.
3.1.4 Adjust
closing delayed action:
beginning at 180°.
•
Increase delayed action: Turn valve clockwise
•
Decrease delayed action: Turn valve counter-clockwise
+
-
+
-
-
+
+
-
-
+
S
BC
L
DE
L
PO
S
S
L
3.2 Adjust hold open (optional)
Fig.6
OFF
ON
3.2.1 Place the hold open mechanism in desired
position and tighten screw.
3.2.2 To adjust hold open force:
•
To increase = turn CW
•
To decrease = turn CCW
3.2.3 To enable: push white slide into hold open
mechanism.
3.2.4 To disable: pull white slide away from hold open
mechanism.