Dormakaba 5750-K Скачать руководство пользователя страница 5

(P/N) 762.128 Rev G 05/17 • © copyright 2009-2018 

4

dormakaba

DEAD/SPRING BOLT 

1.  Mount the dial plate (p/n 2676) centered on the through hole. Attach the dial plate 

with the two mounting screws US 8-32 (US) or the M4-0.7 (metric), and the shoulder 
bushings 
(p/n 2618).

2. Measure total mounting thickness (door thi mounting plate). (Figure 3)
3. Cut the spindle to a length of .700” (17mm) plus the total mounting thickness.

NOTE: 

the spindle must be deburred.

4.  Insert the spindle into the keypad, and route the cable in the groove of the spindle. 
5.  Slide the bearing plate (p/n 2674) over the cable, and press onto the fasteners on the 

Entry Device. 

NOTE: 

It is important to make sure the cable will not rub on the dial plate after 

assembly.
6.  Feed the Entry Device’s cable and spindle through the spindle/cable hole from the 

front of the safe door.

WARNING: 

Spring and blocking pin are NOT installed when Entry Device is used with 

either the dead bolt or spring bolt locks. 
7. Rotate the key pad approx. 30° counter-clockwise and place onto the bushings.
8. Then turn the key pad clockwise until the key pad is vertical (Figure 4). 

9. The spindle should protrude between .300" - .350" (8 - 9 mm) through the safe door.
10.   Slide the cable protector (p/n 2754) over the cable and spindle, until the flat side rests against 

the inside of safe door. Route the cable through the groove of the cable protector.

11.   Gently pull on the cable to assure that there is no excess cable in the spindle hole that would rub 

on the metal door.

12.  Install the lock with the bolt extended onto the spindle. 

INSTALLING BATTERIES

The 3035/3125 Entry Device require either a battery box (2788 or 4001), or a battery/alarm box 
(2789 or 4002) to provide power to the lock.

NOTE: 

The 3125 Entry is not UL listed. The Battery and Battery/Alarm boxes have not been UL 

evaluated.
Mount the battery box inside the safe, and connect the cable coming from the battery box directly 
into the connector port marked BAT on the lock.

Small Battery and Battery/Alarm Box:

1. Open safe door.
2. Remove battery box cover by pulling the front portion away from the safe door.

CAUTION! 

Hold onto the battery connector to avoid pulling the wires out of the board.

3. Connect a new 9-Volt alkaline battery to the battery connector.
4. Push the battery and the leads completely into the battery compartment.
5. Replace the cover and test the lock several times before closing the door.

1.  Key Pad

2.  Bearing Plate

3.  Mounting Screws

4.  Shoulder Bushing

5.  Dial Plate

6. Spindle

7.  Cable Protector

3035 & 3125 Entry Device

(Dead Bolt/Spring Bolt Option)

3125

Cable

protector

Battery

compartment

DOOR

MOUNTING PL

A

TE

Total Mounting Thickness = door thickness

+ mounting plate

Figure 3

Figure 4

2788 Small Battery Box or

2789 Small Battery Alarm Box

4001 Large Battery Box

4002 Large Battery

Alarm Box

Содержание 5750-K

Страница 1: ...Installation Guide Electronic Entry Device LA GARD Basic Gard Series Document Number 762 128 Rev G 05 2018 ...

Страница 2: ...lt ALKALINE batteries only The use of a high quality name brand battery Energizer or Duracell is recommended BASIC TOOLS AND MATERIALS REQUIRED Medium Phillips head screwdriver 2 recommend magnetized tip Small flat file or deburring stone Tape measure or ruler ESD wrist band PREPARATION FOR NEW INSTALLATION IF REQUIRED 1 Use the template provided to establish the exact locations relative to the sp...

Страница 3: ... P N 762 128 Rev G 05 17 copyright 2009 2018 2 dormakaba DIAL RING FRONT HOUSING BASE MOUNTING TEMPLATE ...

Страница 4: ...n the keypad over the mounting screws and slide the keypad housing down Ensure there are no wires or cables trapped between the Entry Device and the safe door 3035 AND 3125 ROUND ENTRY DEVICES NOTE The 3125 entry is not UL listed SWING BOLT 1 Mount the dial plate p n 2676 centered on the through hole Attach the dial plate with the two mounting screws US 8 32 US or the M4 0 7 metric and the shoulde...

Страница 5: ...f safe door Route the cable through the groove of the cable protector 11 0 Gently pull on the cable to assure that there is no excess cable in the spindle hole that would rub on the metal door 12 0 Install the lock with the bolt extended onto the spindle INSTALLING BATTERIES The 3035 3125 Entry Device require either a battery box 2788 or 4001 or a battery alarm box 2789 or 4002 to provide power to...

Страница 6: ...3 and blocking pins p n 2894 into the holes located on the back of the keypad Figure 7 5 Skip this step if the battery door is to be removable Otherwise attach the battery door to the keypad by first inserting the hinge pin into the hole on the battery door and then insert the battery door with hinge pin into the hinge pin hole on the keypad housing adjacent to the locking pin hole See Figure 7 WA...

Страница 7: ...ve spindle and cut as marked in Step 7 10 Reassemble keypad spindle and bearing plate 11 Skip this step if the battery door is to be removable Otherwise attach the battery door to the keypad by first inserting the hinge pin into the hole on the battery door and then insert the battery door with hinge pin into the hinge pin hole on the keypad housing adjacent to the locking pin hole Figure 7 DO NOT...

Страница 8: ...r was installed without the hinge pin it will detach from the Entry Device when it is opened 2 Allow the battery connector and its attached leads to drop down and out of the battery compartment If it does not drop gently pull on the battery connector until it does CAUTION Hold on to battery terminal connector to avoid pulling the wires out of housing 3 Connect a new 9 Volt alkaline battery to the ...

Страница 9: ...f the knob 2 Cut the spindle to a length of 820 20 8mm plus the door thickness Figure NOTE the spindle must be deburred 3 Install the knob assembly using the two 8 32 x 5 16 phillips pan screws 4 Install the lock with the bolt extended onto the spindle placing it flush to the mounting surface Refer to lock installation instructions which are available at www kaba mas com Figure 14 DOOR MOUNTING PL...

Отзывы: