4.2
Activators
Test all connected
activators
in the various program
switch settings.
Perform settings and adjustments
for
the activators
in accordance
with the corresponding
installation
instructions.
4.3
Emergency opening -
operation with back-up battery module
1.
Set the program switch to "OFF" and remove
mains plug.
Lock should not disengage and door should not
open.
?
Set program switch to "AUTOMATIC".
Door should unlock and open.
3.
Re-insert mains plug.
Door should close at creep speed.
4.
Leave program switch in "AUTOMATIC"
setting
and remove mains plug.
Door should open.
4.4
Emergency stop-
operation with backup battery module
1.
Set program switch to "AUTOMATIC"
and
during the closing cycle. operate the
emergency stop switch.
Door should stop and reverse.
4.5
Lock
Set program SWitch to "OFF".
• Door should be locked in closed condition.
In all other program switch settings.
• Door should be unlocked.
The lock can be adapted with the hand terminal
at the
request of the customer.
(See hand terminal
operating
instructions)
4.6
Night-bank
activator
1.
Set program switch to "OFF".
2.
Issue an opening signal uSing the
"NIGHT - BANK" activator.
The door should unlock and open.
The door should close and lock automatically
once
the user has passed through the door or, at the
latest, on expiry of the pre. set
"NIGHT - BANK hold.open
t,me",
3.
Remove mains plug
4.
Issue an opening SIgnal using the
"NIGHT.
BANK" activator.
Door should unlock and open as long as the
NIGHT.
BANK - signal remains live.
With the KT 8 key switch as the activator,
the
door can also be unlocked
if the power is
disconnected.
1.
Push the door closed by hand.
2.
Turn the key switch counter-clockwise.
Door should lock.
5. Further information
The door system performs a self-test
every 4 hours or
at appropriate
times after the system has been
switched on.
In this self-test, an emergency opening cycle is
performed under battery power and the control unit is
checked for integrity.
If the self-test should fail, the
door remains in the open position.
The door can be closed by setting the
program switch to "OFF".
At the next opening signal, a further self-test is
performed.
6. Optional functions
If the functions
described below have been
implemented,
they must be tested as follows.
6.1
Air lock (two doors in tandem)
Depending on the side from which the opening signal
is initiated.
the first door in the access sequence
should initially
open and then close.
Only after the first door has closed should the second
door open and close.
6.2
Presence detector (bell contact)
Check the bell contact by interrupting
the light
barriers.
6.3
Door status monitor
Check the audible or visual door status detectors.
6.4
Panic/emergency
closing
It'
The panic/emergency
closing function
is subject
ill
to special statutory regulations.
Consequently,
it
is imperative
to ensure compliance
with the
relevant national regulations.
The panic/emergency
closing function
must be set
using the DIP switches and hand terminal.
Initiate a NIGHT/BANK
signal in each of the program
switch modes "AUTOMATIC",
"EXIT ONLY", "PARTIAL
OPEN" and "PERMANENT
OPEN".
• The door should close immediately.
The door should not open either when the light barriers
are interrupted
or when a signal is issued
by
radar
detectors.
Cancelling the panic/emergency
closing function:
Set the program switch to
uOFF",
and then back to the
required mode.
Then test all the other functions.
Opening and reversing via the radar detector.
• Reversing via the light barriers.
Содержание ES 100
Страница 1: ...n DORMA ES 90 100...
Страница 2: ...UK training department1 2 25 20044 14 PM DORMA 6...
Страница 3: ...UKT aining Dcpartll1e nt UK training departmentl 2 25 20044 14 PM t A f DORM 7...
Страница 4: ...UK training department1 2 25 20044 14 PM DORMA 8...
Страница 5: ...UK training department1 2 25 20044 14 PM DORMP 9...