background image

M2.5 HEX KEY

Place the hold open

mechanism in desired
position and tighten screw.

SNAP VALVE ADJUSTMENT
WRENCH INSIDE COVER

08280161

3 of 3

09/09

INS NO.

PAGE

Rev.

7

9

To adjust hold open

force, turn clockwise to
increase force, and
counter clockwise to

To enable hold open,

push the white slide into
the hold open mechanism.
To disable hold open,

A

B

C

(HOLD OPEN UNITS ONLY)

Set hold open.

weaken force.

M2.5 HEX KEY

OFF

ON

pull the white slide away

from hold open mechanism.

BACKCHECK OR DELAYED ACTION

NOTE: DELAYED ACTION IS AN OPTIONAL FEATURE.

DECREASE

control when extra time is required to pass through

Optional delayed action offers additional closing speed

the door. All valve adjustments are made with a 3/32"

CAUTION: DO NOT REMOVE VALVES.

DELAYED ACTION

BACKCHECK RANGE

SWEEP (SPEED)

INCREASE

(SPEED)

LATCH

RANGE

(TIME)

ACTION

DELAYED

hex key.

SWEEP & LATCH

POSITIONING VALVE

BACKCHECK (INTENSITY)

RANGE

LATCH

SWEEP

RANGE

DECREASE

INCREASE

should take a minimum of 1.5 seconds.

Closing time from 15° to fully closed (latch range)

generally adjusted to take a minimum of 3 seconds.

Closing time from 90° to 15° (sweep range) is

Adjust sweep and latch valves.

8

(2)

TAB

QTY

NOTE: LEFT HAND INSTALLATION SHOWN. RIGHT

HAND IS A MIRROR IMAGE.

Place cover over closer and fasten securely with

Place tab in cover slot opposite main arm.

screws provided.