D'Orly PCN70 Скачать руководство пользователя страница 5

4

Air Coil Nailer MCN70     

   www.aeroprotools.com

Do not carry the compressor while it is running.
Do not operate the compressor if it is not in a stable position.
Do not operate the compressor on a rooftop or in an elevated position that could allow the unit to fall or be tipped 
over.
Always replace a damaged gauge before operating the unit again.

CAUTION!

Potential hazard that may result in moderate injury or damage to equipment.

Always ensure that the tool has stopped before connecting to the air supply.
Do not wear watches, rings, bracelets, or loose clothing when using any air tool.
Do not overload the tool. Allow the tool to operate at its optimum speed for maximum efficiency.
Do not use a tool that is leaking air, with missing or damaged parts, or that requires repairs.Verify that all screws are 
securely tightened.
For optimal safety and tool performance, inspect the tool daily in order to ensure free movement of the trigger, safety 
mechanisms, and springs.
Always keep your air tools clean and lubricated. Daily lubrication is essential to avoid internal corrosion and possible 
failures.
Ensure the floor is not slippery and wear non-slip shoes. Floors should be kept clean can clear.
Always follow all workshop safety rules, regulations, and conditions when using the tools.
Carry the tool by the handle only. Do not carry the tools with a finger on the trigger. Do not carry the tool by the hose,
magazine or any other parts.
Do not use the tool near or below freezing temperatures, as doing so may cause tool failure.
Do not store the tool in a freezing environment to prevent ice formation on the operating valves of the tool, as doing 
so may cause tool failure.
Handling and storage of oil: Use with adequate ventilation. Avoid contact of oil with eyes, skin, and clothing. Avoid 
breathing spray or mist. Store in a tightly closed container in a cool, dry, well-ventilated area free from incompatible 
substances.

CAUTION!

Potential hazard that may result in moderate injury or damage to equipment.

Disconnect tool from the air supply and turn off the compressor before performing any 
maintenance, or changing accessories, when the tool is not in use, when it is being handed to 
another person, and when it is left unattended. Failure to comply may result in moderate injury or 
damage to equipment.

Use safety goggles and ear protection:

Wear safety glasses with side shields when operating the tool/compressor and verify that others in 
the work area are also wearing safety glasses. Safety glasses must conform to 

American

national standards institute (ANSIZ87.1)

Requirements and must provide protection from flying particles from the front and the sides.
Air powered tools are loud and the sound can cause hearing damage. Always wear ear protection 
to prevent hearing damage and loss. Failure to comply may result in moderate injury.
NOTE: Recycle unwanted materials father than disposing of them as waste. Sort the tools, hoses, and package into 
specific categories and take to the local recycling centre or dispose of them in an environmentally safe way.

Содержание PCN70

Страница 1: ...MANUAL PCN70...

Страница 2: ...lungs if an effective dust mask is not worn Damage to hearing if effective hearing protection is not worn Health defects resulting from vibration emission if the power tool is being used over longer...

Страница 3: ...ersonal safety and preventing equipment problems it is very important to read this manual carefully and understand it thoroughly before using the product the symbols listed below are used to indicate...

Страница 4: ...switch or safety valve for any reason They have been preset at the factory for this compressor s maximum pressure Tampering with the pressure switch or the safety valve may cause personal injury or pr...

Страница 5: ...parts Do not use the tool near or below freezing temperatures as doing so may cause tool failure Do not store the tool in a freezing environment to prevent ice formation on the operating valves of the...

Страница 6: ...o 8 bar 87 to 120psi Do not exceed the maximum or minimum pressures Operating the tool at the wrong pressure too low or too high will cause excessive noise or rapid wear of tool WARNING Potential haza...

Страница 7: ...gen carbon dioxide or any other combustible or bottled gas to power this tool Do not use this tool in the presence of any flammable liquids or gases Keep hands and other parts of the body away from th...

Страница 8: ...the muzzle is not pointing towards the operator or any other person or animals 4 4 Handling the tool Pay attention to 2 Special Reference of these operating instructions Having checked that the fasten...

Страница 9: ...ular lubrication if your tool without using the in liner automatic oilier place 2 or 6 drops of pneumatic tool oil into the air inlet before each work day or after 2 hours of continuous use depending...

Страница 10: ...1 Tighten screws 2 Check and replace O rings or bumper Air leak between body and cylinder cap 1 Loose screws 2 Worn or damaged O rings or seals 1 Tighten screw 2 Check and replace O rings or bumper Bl...

Страница 11: ...10 Air Coil Nailer MCN70 www aeroprotools com Explode drawing Parts list...

Страница 12: ...haft pin 1 14 03 04 27 130 cylinder 1 66 03 04 05 190 spring pin 3x12 1 15 03 04 01 188 o ring 56x3 1 1 67 03 04 36 273 compressed spring 1 16 03 04 19 163 stain ring 1 68 03 04 17 122 limited blocker...

Страница 13: ...agazine 1 40 O ring 6x1 9 1 92 03 04 40 358 nail head protecter 1 41 O ring 6 4 2 1 93 03 04 29 188 gasket shaft 1 42 Valve bush 101 03 04 06 130 gasket 1 43 O ring 8 9x1 9 102 03 04 05 198 spring pin...

Отзывы: