background image

NOTE:

 The default configuration setting for alarm sound is set for 5 minutes 

            before rearming.

Set switches No. 2 and 3 for auto reset alarm time. 

Three setting options: 1.5, 3 or 5 minutes.

If switch No. 1 is off, AL device re-arms with no delay.

6. To change the battery.

   A. Remove end cap and loosen or remove mounting bracket.

   B. Remove cover plate.

   C. Change Battery.

   D. Reassemble.

MODE SELECT SWITCHES

Auto reset time

Rearm time

Option

Function

Mode select 

switches

End Cap 

Bracket Screws

Cover Plate

On

AUTO RESET TIME

Switch No. 3

Switch No. 2

Factory settings shown

Minutes

On

                      WD-OD002(668)

DX-KA3-INST   2020-06

infinite

3

off

on

on

off

1-1/2

on

on

5

off
off

On

Auto reset time

Rearm time

Make sure polarity 

is correct

-

End Cap 

Screws

End Cap

End Cap 

Bracket

9 Volt

Battery

+

-

+

1. Insert the key into the cylinder and turn clockwise to arm unit. Rotate to initial position to remove key.

2. Arming time is of 15 seconds, during which the LED flashes green every 1.5 seconds.

3. A brief sound will indicate that the alarming time is complete. When armed the LED will flash red every 15 seconds.

4. Turn the key counterclockwise to disarm.

5. Changing the battery:

    A beep will sound every 15 seconds to indicate that battery is low. This cannot be shut down by disarming the unit 

    and the sound will stop only when battery is changed.

LED Indicator

Mortise Cylinder

{

OPERATION

OPTIONS

4

Отзывы: