Filling and draining
44
Instruction manual DR-RS
4
gis
The components referred to in these paragraphs are illustrated in
.
4.2
Filling the water
heater
4.2.1
Filling unvented installations
To fill the water heater, proceed as follows.
1. Open the stop valve
in the hot water pipe and, if present, the stop valves
for the circulation pump.
2. Shut drain valve
.
Legend
a
pressure-reducing valve
(mandatory if the mains water
pressure exceeds 8 bar)
b
expansion vessel (mandatory)
c
T&P valve (mandatory)
a) safety valve
d
stop valve (recommended)
e
non-return valve (mandatory)
a) non-return valve
f
circulation pump (optional)
g
drain valve
h
gas valve (mandatory)
i
stop valve (mandatory)
j
temperature gauge
(recommended)
k
top to bottom recirculation
pump (optional)
l
top box
m
hot water draw-off points
n
condensation drainage
o
expension valve (mandatory)
p
water tank
q
float valve
r
3-way venting valve (optional)
s
overflow pipe
a
cold water supply
b
hot water outlet
c
circulation pipe
d
gas supply
e
flue gas discharge
Figure 4.1
Installation diagrams
UNVENTED
IMD-0066
VENTED
IMD-0065