Introduction

Instruction manual DR-LA

47

gis

6

Status of the water 
heater

6.1

Introduction

Topics covered in this chapter:

6.2 Operating states

;

6.3 Error states

;

6.2

Operating states

The water heater has three operating states, namely:

ISOLATED

In this state the water heater is off and all components are electrically dead. 
The isolator (switch between the water heater and the power supply) is 
turned off. On the control panel:
-

the ON/OFF switch is at 

position 0

;

-

the green LED is off.

OFF

In this state, the frost protection is activated. The isolator is set to position I. 
On the control panel:
-

the ON/OFF switch is at 

position 0

;

-

the green LED is illuminated.

ON

In this state the water heater continuously fulfils the demand for heat. On the 
control panel:
-

the ON/OFF switch is at 

position I

;

-

The water temperature can be set by turning the rotary knob on the 
control thermostat, see paragraph

5.5 Control thermostat

;

-

the green LED is illuminated.

6.3

Error states

If the water heater has an error the heater will not operate. The frost protection 
will also be out of operation.
If the water heater should go into an "error" state, you will be unable to 
continuosly draw hot water. These error conditions are divided into three 
groups:

Lockout error due to the flue gas thermostat

The lockout (push button) of the flue gas thermostat in the draught diverter 
has been activated. See paragraph 

5.7 Flue gas thermostat reset button

After removing the cause, the push button must be pressed to re-start the 
water heater.

Lockout errors of the burner control

In this event, the red error LED on the control panel will be illuminated. The 
burner control is locked out. 
After eliminating the cause. the water heater must be returned to service by 
pressing the reset button (see 

5.6 Burner control reset button

).

Blocking error due to high limit thermostats

You can recognise this status by the fact that the water heater will not start 
operation, despite the water temperature being lower than you have set with 
the control thermostat (see 

5.5 Control thermostat

).

This error disappears automatically once the high limit thermostat resets 
itself, after which the water heater re-starts.

gis

Содержание DR-LA 110

Страница 1: ...TURAL GAS I2H LPG I3 NOTE THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING COMMISSIONING OPERATING OR SERVICING EQUIPMENT THIS WATER HEATER IS FOR USE ON GROUP H NATURAL GAS 2ND FAMILY...

Страница 2: ...2...

Страница 3: ...2 5 2 Vented installation 14 2 5 3 Temparature and Pressure valve T P valve 14 2 6 Indicators and Alarms 14 2 6 1 Volt Free Contacts 14 2 7 Options 15 2 7 1 LPG 15 2 7 2 Unvented Supply 15 2 7 3 Top t...

Страница 4: ...3 1 Draining unvented installations 40 4 3 2 Draining vented installations 41 5 Controls 43 5 1 Introduction 43 5 2 Control panel 43 5 3 Explanation of the symbols 44 5 4 ON OFF switch 44 5 5 Control...

Страница 5: ...g the heater 58 9 4 Gas side maintenance 59 9 4 1 Introduction 59 9 4 2 Cleaning the burners 59 9 4 3 Cleaning the orifices 60 9 4 4 Checking the flue baffles 60 9 5 Finalising maintenance 60 A Append...

Страница 6: ...6 Instruction manual DR LA gis...

Страница 7: ...al injury and damage to the water heater 1 2 What to do if you smell gas Warning Whenever there is a smell of gas No naked flames No smoking Avoid causing sparks Do not use any electrical equipment or...

Страница 8: ...ing 70 kW BS 5440 Installation and maintenance of flues and ventilation for gas appliances of rated input not exceeding 70 kW net 1st 2nd and 3rd family gases Part 1 Flues Part 2 Ventilation Institute...

Страница 9: ...allation Based on this check the best maintenance frequency can be determined n Caution Regular maintenance extends the service life of the water heater Both the end user and the service and maintenan...

Страница 10: ...use it 6 Status of the water heater gis This chapter describes each status state that the water heater may be in and how to respond if necessary 7 Starting up and shutting down gis This chapter descri...

Страница 11: ...R LA 11 gis 2 Functioning of the water heater 2 1 Introduction Topics covered in this chapter Functional description of the water heater The water heater s heating cycle Protection for the water heate...

Страница 12: ...as is injected into the bar burners the primary air required for combustion is also drawn in 1 Additional air is drawn through the openings in the burner tray The Legend a flue gas discharge b draught...

Страница 13: ...ignited by the hot surface igniter z and the water becomes heated A soon as Twater exceeds Tset the thermostat will open once more The heat demand will cease and the burner control will stop the heat...

Страница 14: ...ter A non return valve prevents excessive pressure in the water supply system This valve also prevents water from flowing backwards from the heater into the cold water supply system The pressure reduc...

Страница 15: ...ure reducing valve non return valve expansion vessel expansion relief valve and pressure temperature relief valve to enable the heater to be coupled directly to the mains water For details see 2 5 1 2...

Страница 16: ...Functioning of the water heater 16 Instruction manual DR LA 2 gis...

Страница 17: ...ssure and burner pressure Conversion to a different gas category n Caution Starting up the water heater is described in chapter 7 Starting up and shutting down 3 2 Packaging To avoid damaging the wate...

Страница 18: ...ater it is recommended that the following clearances are observed see Figure 3 2 AA around the water heater s control column and cleaning openings 100 cm BB around the water heater itself 50 cm Above...

Страница 19: ...kage from the it and or connections can cause damage to the immediate environment or floors below the level of the boiler room If this is the case then the water heater should be installed above a was...

Страница 20: ...ns The water heater is supplied without accessories Check the dimensions and other specifications for the accessories to be used based on Figure 3 2 and Tabel 3 5 Figure 3 2 Plan and elevation of the...

Страница 21: ...ning opening centre mm 770 770 770 770 780 855 855 R Height of the drain valve centre mm 500 500 500 500 520 595 595 S Height of the T P plug centre mm 1550 1755 1550 1755 1585 1660 1660 1 Cold water...

Страница 22: ...DR LA 3 is Electrical power consumption W 30 60 Supply voltage VAC 230 15 10 Mains frequency Hz 50 1 Hz Table 3 4 General and electrical data Continued DESCRIPTION Unit DR LA 30 DR LA 40 DR LA 45 DR...

Страница 23: ...king plate 2 Burner pressure regulator 3 High Low control 1 2 or 3 1 1 1 1 1 1 3 Nominal load gross kW 40 9 54 2 66 9 79 2 94 3 121 2 135 7 Nominal output kW 32 0 42 0 51 8 61 4 73 1 93 9 106 4 Burner...

Страница 24: ...ea non return valve f circulation pump optional g drain valve h manual gas valve mandatory i stop valve mandatory j temperature gauge recommended k top to bottom recirculation pump optional l draught...

Страница 25: ...side See b in Figure 3 3 n Caution Insulating long hot water pipes prevents unnecessary energy loss 1 Optional fit a temperature gauge j to be able to check the temperature of the tap water 2 Fit the...

Страница 26: ...ck the temperature of the tap water 3 Fit a stop valve i in the hot water outlet pipe for use when servicing 4 If a circulation pipe is to be fitted then refer to paragraph 3 7 4 3 7 4 Circulation pip...

Страница 27: ...t and sensor that are supplied must be fitted in the draught diverter 3 9 2 Fitting the draught diverter The draught diverter can be positioned according to preference After positioning the draught di...

Страница 28: ...n area where this is permitted for this category of water heater 3 9 3 Flue gas thermostat assembly Attached to the control column is a plastic bag containing the flue gas thermostat with sensor and r...

Страница 29: ...m the mains to the phase of the water heater and the neutral N of the mains to the neutral of the water heater There should also be no potential difference present between neutral N and earth A If thi...

Страница 30: ...to the mains voltage by means of a permanent electrical connection A double pole isolator with contacts gaps of at least 3 mm must be fitted local to the water heater The power cable must have cores o...

Страница 31: ...g up for the first time and following conversion you must always check the supply pressure and burner pressure If necessary adjust these to be certain of optimum performance of the water heater cNote...

Страница 32: ...the manifold test nipple h n Caution All gas pipes should be bleeded and free of leakage 4 Connect a pressure gauge to test nipple 5 Open the gas supply 6 Switch on the power to the water heater usin...

Страница 33: ...om Tabel 3 5 15 If the pressure reading is not correct repeat steps 13 and 14 until the correct pressure is attained 16 Fit the cap b on the burner pressure regulator 17 Shut down the water heater by...

Страница 34: ...ield the condensation tray can be temporarily loosened to simplify assembly of the burner 6 Remove the burners one by one from their brackets at the front To do this you first move them away from you...

Страница 35: ...regulator need to be replaced Unscrew the connector e from the gas control Either remove the blank plate f or burner pressure regulator d Either fit the blank plate or burner pressure regulator suppl...

Страница 36: ...as to natural gas 1 Perform steps 1 through 9 of paragraph 3 12 2 Conversion to a different gas category DR LA 30 through 95 2 Detach the high low control b 3 Fit the burner pressure regulator a inclu...

Страница 37: ...this cable 7 Fit the stop plug from the conversion set in the place of the metric strain relief 8 Connect the cables of the gas control valve the hot surface igniter and flame probe to the 6 terminal...

Страница 38: ...ol valve the hot surface igniter and the flame probe from the 6 terminal connector strip 6 and the strain relief 7 5 Fit the timers 4 including cable harness plus 9 terminal connector strip 6 from the...

Страница 39: ...urn valve f circulation pump optional g drain valve h manual gas valve mandatory i stop valve mandatory j temperature gauge recommended k top to bottom recirculation pump optional l draught diverter m...

Страница 40: ...2 2 Filling vented installations To fill the water heater proceed as follows 1 Open the stop valve i in the hot water pipe and if present the stop valves d for the circulation pump 2 Shut drain valve...

Страница 41: ...me service activities require the water heater to be drained The procedure is as follows 1 Shut the water heater down by putting the On Off switch to position 0 2 Switch the mains isolation off 3 Shut...

Страница 42: ...Filling and draining 42 Instruction manual DR LA 4 gis...

Страница 43: ...tion of the symbols 5 4 ON OFF switch 5 5 Control thermostat 5 6 Burner control reset button 5 7 Flue gas thermostat reset button 5 2 Control panel Figure 5 1 shows the control panel The panel consist...

Страница 44: ...control panel will illuminate After eliminating the cause of the error you can reset the water heater using the reset button n Caution Before resetting always eliminate the cause of the error To ident...

Страница 45: ...n the flue gas thermostat will immediately lock out again The water heater will then automatically start up again if there is a demand If this does not happen refer to chapter 8 Troubleshooting for a...

Страница 46: ...Controls 46 Instruction manual DR LA 5 gis...

Страница 47: ...an error the heater will not operate The frost protection will also be out of operation If the water heater should go into an error state you will be unable to continuosly draw hot water These error...

Страница 48: ...detailed overview of error states please refer to chapter 8 Troubleshooting If as end user you find the water heater in an error status you may attempt to re start the water heater by pressing the re...

Страница 49: ...e Isolate the water heater from the power supply Shut the water heater down for a longer period 7 3 1 Shut the water heater down for brief periods OFF mode To shut the water heater down for a brief pe...

Страница 50: ...perature falls below the set temperature e g 60 C causing the control thermostat to close The burner control now detects a heat demand and starts the heating cycle 2 After heat demand is detected the...

Страница 51: ...errors of the burner control In this event the red error LED on the control panel will be illuminated The burner control is locked out After eliminating the cause the water heater must be returned to...

Страница 52: ...No naked flames Warning Ventilate the boiler room n Caution Immediately contact your installer or local gas company Water leakage Leakage from one of the water connections threaded Tighten the thread...

Страница 53: ...y better ventilating the boiler room Table 8 1 General errors Page 2 of 2 Symptom Cause Solution Remark Table 8 2 No hot waterPage 1 of 2 Symptom Cause Solution Remark Green LED OFF and Red LED OFF No...

Страница 54: ...l Check the gas control wiring 2 No ignition Check whether the hot surface igniter lights up Check the power supply to the hot surface igniter Check the wiring of the hot surface igniter 3 No flame de...

Страница 55: ...temperature setting Tset is too low Set the control thermostat to a higher setting See paragraph 5 5 Control thermostat Hot water supply used up 1 Reduce the rate of hot water consumption Allow the wa...

Страница 56: ...is Instruction manual DR LA 56 Warning Maintenance may only be performed by a qualified service and maintenance engineer...

Страница 57: ...ing steps 1 Put the ON OFF switch on the control panel to position 0 2 Set the control thermostat note the original setting to the highest position and put the ON OFF switch back to position I 3 If th...

Страница 58: ...e them 12 Now also check the flue baffles Replace them if necessary See paragraph 9 4 4 Checking the flue baffles 13 Fit a new sealing ring around the edge of the hot water tank and replace the cover...

Страница 59: ...g a suitable cleaner 7 Close the cleaning opening To avoid damage to the tank the bolts that fasten the lid should be tightened with a torque no greater than 50 Nm Use suitable tools for this To prope...

Страница 60: ...of paragraph 9 3 2 Checking the anodes 2 Remove the flue baffles from the water heater 3 Check the flue baffles for rust and remove any which is present 4 Check the flue baffles for wear and replace...

Страница 61: ...Instruction manual DR LA 61 A Appendices 1 1 Introduction This appendix contains The Electrical diagram DR LA is...

Страница 62: ...10A B Frost thermostat C Control thermostat D On Off switch E Safety thermostat F High limit thermostat G Gas valve H Hot surface igniter J Flame probe K Error detection L On detection M Reset button...

Страница 63: ...mit thermostat G Gas valve H Hot surface igniter J Flame probe K Error detection L On detection M Reset button N Combustion products discharge safety device O Relay Max 250V 10A P High low control Q T...

Страница 64: ...Appendices 64 Instruction manual DR LA A is...

Отзывы: