Introduction
Instruction manual DR-LA
47
gis
6
Status of the water
heater
6.1
Introduction
Topics covered in this chapter:
•
•
;
6.2
Operating states
The water heater has three operating states, namely:
•
ISOLATED
In this state the water heater is off and all components are electrically dead.
The isolator (switch between the water heater and the power supply) is
turned off. On the control panel:
-
the ON/OFF switch is at
position 0
;
-
the green LED is off.
•
OFF
In this state, the frost protection is activated. The isolator is set to position I.
On the control panel:
-
the ON/OFF switch is at
position 0
;
-
the green LED is illuminated.
•
ON
In this state the water heater continuously fulfils the demand for heat. On the
control panel:
-
the ON/OFF switch is at
position I
;
-
The water temperature can be set by turning the rotary knob on the
control thermostat, see paragraph
;
-
the green LED is illuminated.
6.3
Error states
If the water heater has an error the heater will not operate. The frost protection
will also be out of operation.
If the water heater should go into an "error" state, you will be unable to
continuosly draw hot water. These error conditions are divided into three
groups:
•
Lockout error due to the flue gas thermostat
The lockout (push button) of the flue gas thermostat in the draught diverter
has been activated. See paragraph
5.7 Flue gas thermostat reset button
.
After removing the cause, the push button must be pressed to re-start the
water heater.
•
Lockout errors of the burner control
In this event, the red error LED on the control panel will be illuminated. The
burner control is locked out.
After eliminating the cause. the water heater must be returned to service by
pressing the reset button (see
5.6 Burner control reset button
•
Blocking error due to high limit thermostats
You can recognise this status by the fact that the water heater will not start
operation, despite the water temperature being lower than you have set with
the control thermostat (see
This error disappears automatically once the high limit thermostat resets
itself, after which the water heater re-starts.
gis
Содержание DR-LA 110
Страница 2: ...2...
Страница 6: ...6 Instruction manual DR LA gis...
Страница 16: ...Functioning of the water heater 16 Instruction manual DR LA 2 gis...
Страница 42: ...Filling and draining 42 Instruction manual DR LA 4 gis...
Страница 46: ...Controls 46 Instruction manual DR LA 5 gis...
Страница 64: ...Appendices 64 Instruction manual DR LA A is...