16. Start the water heater (see paragraph
3.12.3
Conversion to a different gas category, DR-LA110
Introduction
This paragraph describes the:
•
Conversion from LP gas to natural gas
•
Conversion from natural gas to LP gas
Conversion from LP gas to natural gas
1. Perform steps 1 through 9 of paragraph
3.12.2 Conversion to a different gas
.
2. Detach the high-low control
3. Fit the burner pressure regulator
including the sealing gasket from the
conversion kit. Attach the burner pressure regulator to the gas control
valve
using the two small screws supplied.
Legend
a
burner pressure regulator
b
high-low control
c
gas control valve
Figure 3.11
Conversion of gas control DR-LA110