While key lock allows the user to avoid any undesired and potentially hazardous tempering with, if the controller is 
installed in a publicly accessible place. To disable key lock, in INFO menu, set LOC=YES parameter. 

To activate the 

keyboard again, set LOC parameter to NO.

 

 

Unlock keyboard

 

- press the 

 button until 

LOC

 message is displayed, 

- then, while holding the 

 button, press the 

 button. 

- to exit this menu, press the 

 button or wait 10 seconds. 

 

  MOUNTING PRODUCT 

 

 

Place the granite plate with cooling module mounted on a support structure (framing, cabinet, etc.) 
Control  panel  of  the  device  is  suitable  to  be  mounted  in  a  support  structure  or  decorative  structures. 

Dimensions  of  mounting  hole  for  control  panel:  125x75.  Make  sure  to  install  control  panel  cover  on  the 
inside. 

When  encasing  devices  make  sure  that  adequate  ventilation  of  the  unit  is  provided.  In  the  encasing, 

opposite  the  condenser,  drill  ventilation  (through)  holes  to  ensure  free  movement  of  cooling  air  for  the 
condenser. The area of holes ensuring free movement of cooling air should not be smaller than the area of 
outline of the condenser. Make sure to position the unit at least 25cm from the wall. 

 

 

  PREPARATION FOR STARTUP. CLEANING AND MAINTENANCE 

Commissioning  and  maintenance  can  be  carried  out  by  personnel  in  charge  on  condition  the  below 

recommendations  are  strictly  followed.  The  manufacturer  will  decline  all  responsibility  for  any  operations 
performed on the device without following recommendations herein. 

 
Before any maintenance works, make sure the device is disconnected from power supply. Do 
not remove any protection systems

 

Before  commissioning  remove  protective  foil.  Clean  external  and  internal  surfaces  using  warm  water 

with  degreaser  for  washing  kitchenware,  with  a  soft  cloth,  following  the  polished  direction,  rather  than  in 

Mounting sequence: 

1. Before foamed housing is mounted, bond discharge pipe in granite plate. 
2. Spread thermal-conductivity compound evenly over the aluminium plate, 

leaving 20mm space from edge of the plate. 
3. Apply adhesive on free space of the aluminium plate. 

4. Bond the housing to the granite plate and bolt using bolts M6 + serrated 
washers. 

 

Granite plate 

Foamed housing

 

Tube 

 20x2 L=100

 

Detail A

 

Thermal-conductivity compound  

 

Adhesive

 

Aluminium plate

 

Sikaflex-11FC 

adhesive

 

Serrated washer

 

Bolt M6

 

Adhesive

 

 

Содержание DM-99006

Страница 1: ...EN DORA METAL Sp ka z o o Edition 11 2017 INSTRUCTION MANUAL CHILLING EQUIPMENT COOLING MODULE DM 99006 ISO 9001 2000...

Страница 2: ...manufacturer cannot be held responsible for use of the device for purposes other than intended not in accordance with the instructions or recommendations It is forbidden to cover shutter of condensin...

Страница 3: ...INTENDED USE 4 OPERATION OF REFRIGERATION SYSTEM 4 SETTING CHAMBER TEMPERATURE 4 MOUNTING PRODUCT 5 PREPARATION FOR STARTUP CLEANING AND MAINTENANCE 5 CONNECTING TO WIRING SYSTEM 6 USAGE 6 TRANSPORT...

Страница 4: ...temperature in the chamber To set a required temperature in the chamber Short press the button to display the set temperature By holding the button and using buttons set a desired parameter value the...

Страница 5: ...should not be smaller than the area of outline of the condenser Make sure to position the unit at least 25cm from the wall PREPARATION FOR STARTUP CLEANING AND MAINTENANCE Commissioning and maintenan...

Страница 6: ...have it replaced by a service technician or a qualified person holding adequate qualifications The devices are fitted with a terminal for connection of external equipotential bonds marked with Before...

Страница 7: ...held responsible for damage of the condenser resulting from failure to keep the condenser clean All settings necessary for a normal operation of the device have been carried out by the manufacturer It...

Страница 8: ...erant R134a GWP ODP 1430 0 Amount of factory filled refrigerant 0 3 kg CO2 equivalent 0 43 Added amount of refrigerant __ kg CO2 equivalent __ t Total amount of refrigerant in the circuit __ kg CO2 eq...

Страница 9: ...NG DIAGRAM Czujnik komorowy Chamber sensor Czujnik parownikowy Evaporator sensor AGREGAT SKRAPLAJ CY CONDENSING UNIT OZNACZENIE KOLOR W PRZEWOD W WIRING COLOURS Barwa Colour niebieska blue br zowa bro...

Страница 10: ...w dora metal pl e mail info dora metal pl serwis dora metal pl Service tel 602 286 179 Information herein is subject to change by DORA METAL without prior notice No part of this document can be reprod...