Operation & Maintenance Manual
Troubleshooting Chart
Bold Headings depict the COMPLAINT - Subheadings indicate CAUSES
NOTE: Subheadings suggest sequence to follow troubleshooting.
Table 1: Unit Shutdown
Cause
Corrective Action
Out of Fuel.
Add CLEAN diesel fuel.
Compressor Oil Level Too High.
Add correct oil
Compressor Oil Temp. Too High
See Table 4
Engine Water Temp. Too High
Check coolant level. If necessary, Add.
Loose Wire Connection
Wiggle wires at switches & connector blocks. Make
repairs.
Defective Discharge Air Temp.
Switch
Replace switch.
Defective Engine Oil Pressure Switch Replace switch.
Broken Engine Fan Belt
Replace fan belt.
Engine Oil Pressure Too Low
Check engine oil level and add if necessary.
Malfunctioning Relay
Replace relay.
Blown Fuse
Replace fuse/Check for Short.
Engine Malfunctioning
Contact Service Technician
Airend Malfunctioning
Contact Service Technician
60
Содержание P250/HP210WKUB-EX-T2
Страница 2: ......
Страница 3: ......
Страница 6: ...Foreword 5 ...
Страница 9: ...8 ...
Страница 10: ...Drawbar Information 9 ...
Страница 13: ...12 ...
Страница 14: ...Safety 13 ...
Страница 23: ...Operation Maintenance Manual Safety 22 ...
Страница 24: ...Safety Operation Maintenance Manual 23 ...
Страница 25: ...Operation Maintenance Manual Safety 24 ...
Страница 26: ...Safety Operation Maintenance Manual Decal Symbols Graphic Form and Meaning of ISO Symbols 25 ...
Страница 27: ...Operation Maintenance Manual Safety 26 ...
Страница 28: ...Safety Operation Maintenance Manual 27 ...
Страница 29: ...Operation Maintenance Manual Safety 28 ...
Страница 30: ...General Data 29 ...
Страница 33: ...32 ...
Страница 34: ...Operating Instructions 33 ...
Страница 43: ...42 ...
Страница 44: ...Maintenance 43 ...
Страница 53: ...Operation Maintenance Manual Maintenance Maintenance Schedule 52 ...
Страница 54: ...Lubrication 53 ...
Страница 58: ...Troubleshooting 57 ...
Страница 64: ...WARRANTY 63 ...
Страница 65: ...64 ...
Страница 66: ...65 ...
Страница 67: ...66 ...
Страница 69: ......
Страница 70: ......