SL4750183 -EN

 

5. Disconnect Controller and Test. 
 

Exit DSE Configuration Suite and remove USB connection 
cable from back of controller. Re-connect battery and start 
machine. 
 
Machine should start without any alarms or shutdowns. 
The engine temperature display should read “xxxx” or “----
” until engine warms to approx. 39˚C. Once Engine 
reaches temperature engine temperature will display and 
operate as normal. 
 

Fig 9. DSE 4510MKII Engine Temperature Display 

 

 

 
 

 

With the “Temperature Sensor Open Circuit Alarm” 
disabled there is a risk of a temperature sensor fault 
going undetected. During this temporary period when 
“Temperature Sensor Open Circuit Alarm” is disabled 
it is important to regularly check the engine 
temperature display and coolant level on machine. If 
the display is reading “xxxx” or “----”   when engine is 
running hot- it is recommended to stop the machine 
and investigate Temperature Sensor and associated 
connections. It is also recommended to check coolant 
level more regularly during this temporary period until 
a final solution has been released by DOOSAN 
Portable Power. 
 
 

MODIFICATION COMPLETE