3-9
Hydraulic System Warm-up
The correct operating temperature of the hydraulic oil is 50° -
80°C (120° - 175°F). Make sure to follow the procedures listed
here for hydraulic fluid warm-up.
1.
Run engine for approximately five minutes set at the
middle of the speed range, without a load.
2.
Set safety lever (1, Figure 14) on "UNLOCK" position.
3.
Slowly cycle boom, arm and bucket cylinders about five
times without a load to circulate the oil through the system.
Do this for five minutes.
4.
Check for clearance and fully raise the front attachment.
Swing clockwise 3 revolutions. Swing counterclockwise 3
revolutions.
5.
Travel forward and reverse at low speed for two
revolutions of the drive sprocket.
WARNING
If a problem or abnormal operation occurs, immediately
shut down engine. Allow excavator to reach normal
operating temperature before starting work, especially in
cold weather.
HAOB410L