OP000599
Inspection, Maintenance and Adjustment
4-84
VENTING AND PRIMING
HYDRAULIC SYSTEM
Main System Pump
NOTE:
If pump is run without sufficient oil in the main
hydraulic pump, damage can occur. Always vent
pump of air after draining hydraulic system.
1.
With the engine stopped, remove vent plug (Figure 143) to
see if any oil is present.
2.
If oil is not present, fill pump with oil through port (Figure
143).
3.
Install vent plug (Figure 143) first.
4.
Start engine and run it for several minutes at low idle
engine speed. This will pressurize the hydraulic oil tank
and system.
5.
Slowly loosen vent plug (Figure 143) several turns, until
hydraulic oil flows out of plug. This shows that air has been
released.
6.
Tighten the plug (Figure 143).
Hydraulic Cylinders
1.
Run engine at low idle. Extend and retract each cylinder to
within 100 mm (4 in) of fully stroking it 4 - 5 times.
2.
Operate fully extend and retract each cylinder 3- 4 times.
3.
Repeat procedure until cylinders extend and retract
smoothly.
Figure 143
FG009595
IMPORTANT
If cylinders are operated in high idle after the hydraulic
system has been drained or the cylinder has been rebuilt,
damage to piston packing and seals may occur. Always
vent air from cylinders at low idle and at a slow speed.
Содержание DX140LC
Страница 2: ......
Страница 67: ...OP000597 2 3 Operating Controls ...
Страница 87: ...OP000597 2 23 Operating Controls ...
Страница 122: ...OP000597 Operating Controls 2 58 CD Player Optional AST DIR FG000109 Figure 123 ...
Страница 184: ...OP000598 Operation 3 48 ...
Страница 193: ...OP000599 4 9 Inspection Maintenance and Adjustment ...
Страница 272: ...OP000599 Inspection Maintenance and Adjustment 4 88 ...
Страница 278: ...OP000600 Transportation 5 6 ...
Страница 284: ...OP000013 Troubleshooting 6 6 ...
Страница 292: ...OP000601 Specification 7 8 ...