background image

5.3 

Isolating Noise Problems 

If noise or hum is present on the resident’s phone line after installation of the 1812 telephone 
intercom system, use the procedure on the next page to find and correct the source of the noise. This 
procedure will require the use of a telephone test set (DoorKing p/n 1800-050 or equivalent). 
Typically, noise is usually introduced into the system because of incorrect wiring, poor quality of wire, 
wire runs exceeding maximum distances, phone and high voltage power wires running in the same 
conduit or in very close proximity to each other, a wrong type transformer was substituted, or the 
phone lines, power lines or 1812 circuit board is grounded. 

 
 

1.  Place the BYPASS switch in the BYPASS mode (slide switch to right). If noise goes 

away, problem is with phone in/out wiring, power wiring, or 1812 unit.  Place the BYPASS 
switch in the ENTRY SYSTEM mode (slide switch to left) and proceed to step 3.  If noise 
is still present when switch is in the bypass mode, disconnect C.O. wires and HOUSE 
wires from bypass switch.  Connect the C.O. wires to the HOUSE wires. If the noise goes 
away, the bypass switch is bad and needs to be replaced.  If noise is still present, contact 
the telephone company for service. 

2.  Remove all external items connected to the 1812 unit, such as back-up batteries, relay 

connections, push button switches, or time clocks. All terminals should be free of any 
wiring except terminals 1 and 2 (PHON IN WIRES), terminal 3 (CASE GROUND WIRE), 
terminals 4 and 5 (PHON OUT WIRES), and terminals 17 and 18 (16 VAC POWER 
WIRES). If noise is still present, proceed to step 2.  If noise is gone, the source of the 
noise is one of the external devices that were connected to the 1812.  Reconnect them 
one at a time until you find the item that is the source of the noise. 

3.  Remove the PHON OUT wires from terminals 4 and 5 at the 1812 unit.  Connect your 

handy phone directly to the loose PHON OUT wires.  The wires should be dead and you 
should not have any dial tone on these wires.  If you do have dial tone, the 1812 is wired 
incorrectly.  Disconnect power immediately and refer to the wiring information section in 
this manual. 

4.  Disconnect your handy phone from the PHON OUT wires (step 3).  Remove the PHON 

IN wires from terminals 1 and 2 at the 1812 unit.  Connect the PHON IN wires to the 
PHON OUT wires.  This completely disconnects the 1812 unit from the circuit.  Check the 
phones in the house.  If the noise is gone, problem is with or in the 1812 unit, or with the 
power supply or power wiring.  Reconnect the PHON IN wires to terminals 1 and 2, and 
the PHON OUT wires to terminals 4 and 5, then proceed to step 5.  If the noise is still 
present, problem is with the PHON IN or PHON OUT wires running from the 1812 unit to 
the bypass switch.  These wires will need to be replaced and/or re-routed to correct the 
problem. 

5.  Disconnect the 16 VAC wires from terminals 17 and 18.  If the phone line is now clear, 

the problem is in the 16 VAC power run.  Check the power lines for a ground, or running 
next to high voltage wires, or an improper wire size and insulation, or too long of a wire 
run.  If noise is still present, go to step 6. 

6.  If noise is still present at this step in the trouble shooting sequence, this would indicate a 

short to ground internally in the 1812 unit.  Remove the 8-pin front panel terminal strip 
from the circuit board, and check for noise again.  If noise is gone, this would indicate a 
problem with the microphone board, speaker, push button, or lights on the front panel 
assembly.  Check for any shorts to ground on any of these components or wiring.  Check 
to be sure that none of the wires are pinched.  If noise is still present, check the wires 
entering the back of the 1812 box and be sure that none are pinched.  Be sure that these 
wires are not touching the back of the 1812 circuit board, possibly causing a short to 
ground.  If all of the above steps fail to identify the source of noise, contact DoorKing for 
additional assistance. 

 
 

1812-161-E-1-10  

Page 

45 

Содержание 1812 PLUS

Страница 1: ...Intercom Access Control System Owner s Manual DoorKing Inc 120 Glasgow Avenue Inglewood California 90301 U S A Phone 310 645 0023 Fax 310 641 1586 www doorking com P N 1812 161 REV E 1 10 Copyright 2...

Страница 2: ...Page 2 1812 161 E 1 10...

Страница 3: ...nual without notice and without obligation of DoorKing Inc to notify any persons of any such revisions or changes Additionally DoorKing Inc makes no representations or warranties with respect to this...

Страница 4: ...the Master Code 21 Programming Guide Table 22 2 1 Programming Information 2 1 1 Programming from the Keypad 23 2 1 2 Programming with a Touch Tone Telephone 23 2 2 System Parameter Programming 2 2 1...

Страница 5: ...s 36 Section 3 Adjustments Speaker Volume and Microphone Gain 37 Section 4 User Instructions 4 1 Resident Operating Instructions 4 1 1 Granting or Denying a Guest Access 39 4 1 2 Call Waiting 39 4 1 3...

Страница 6: ...The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian...

Страница 7: ...inches above grade to the top of the keypad 3 If the clear floor space allows parallel approach by a person in a wheelchair the maximum high side reach shall be 54 inches above grade to the top of th...

Страница 8: ...out telephone numbers Answer machine bypass feature Allows the homeowner to log into the 1812 even after an answering machine has already picked up the call Two internal relays allow the system to con...

Страница 9: ...ard 3 Remove the control board from the housing CAUTION The control board contains static sensitive components Discharge any static electricity from your hands by touching a proper ground device befor...

Страница 10: ...2 must pass through the by pass switch Wire the by pass switch per the wiring instructions in this manual Mount the by pass switch in a location that is easily accessible by the homeowner In case of t...

Страница 11: ...ensions Surface Mount 1 0 7 8 9 6 5 4 3 2 10 0 5 25 2 875 6 125 3 0 5 0 2 5 2 5 875 1 25 1 31 875 Dia Surface Mount Curved 11 0 6 25 6 75 3 375 5 5 2 5 2 5 1 0 7 8 9 6 5 4 3 2 875 875 1812 161 E 1 10...

Страница 12: ...Flush Mount Rough in Box 10 25 7 5 4 5 3 5 5 0 2 625 1 25 Dia Flush Mount 1 2 3 6 5 4 9 8 7 0 9 25 12 0 4 25 3 5 875 Dia 7 25 6 25 10 0 2 5 5 0 Page 12 1812 161 E 1 10...

Страница 13: ...Wall Mount 10 75 3 5 7 375 1 2 3 6 5 4 9 8 7 0 2 5 2 5 1 125 1812 161 E 1 10 Page 13...

Страница 14: ...member this is that the colors run from the sky to the earth BLUE sky comes first ORANGE sunset second GREEN grass third BROWN earth last Tip and Ring are common terms in the telephone service industr...

Страница 15: ...e 16 AWG wire 1 6 Surge Suppression and Grounding Proper grounding and the use of surge suppressers can significantly reduce the chance of component failure because of static charges or surges To be e...

Страница 16: ...use wire that is intended for indoor applications Recommend Cat5e Gel Filled flooded UV Resistant Direct Burial Cable in conduit DO NOT run telephone wires and high voltage wires in the same conduit C...

Страница 17: ...each must have a unique MASTER CODE The 1812 that is connected directly to the house phones must have its Number of Rings programming see 2 2 8 set for 1 less than the other 1812 units in the system 1...

Страница 18: ...VAC transformer DO NOT power this device with a 24 VAC transformer or power source 2 Magnetic locks or electric strikes must be powered from a separate UL Listed power transformer Do not power strike...

Страница 19: ...4 15 16 17 18 Mic Vol Master Code 1 2 3 4 5 6 7 8 9 1011 Speaker Vol Keypad Telephone Mode Telephone Mode Intercom Mode 2 Magnetic locks or electric strikes must be powered from a separate UL Listed p...

Страница 20: ...or its programmed strike time 8 Switch Input Relay 2 A switch closure across terminals 8 9 will activate relay 2 for its programmed strike time 9 12 VDC Battery Negative Also common for terminals 7 8...

Страница 21: ...the four digit number required to gain access to the system memory The master code can only be programmed from the system keypad Default setting is NONE You MUST program a Master Code 1 Open the cabi...

Страница 22: ...elete Single Phone Number from Directory Codes 24 50 4 2 2 3 2 N A Delete All Phone Numbers from Directory Codes 24 50 4 3 2 3 3 N A Devices Section 2 4 Description Command Section Default Value Progr...

Страница 23: ...en followed correctly and with a long tone beeeeeep when the programming step is ended 2 1 2 Programming with a Touch Tone Telephone Follow these steps when programming the 1812 Plus from the resident...

Страница 24: ...Systems Default setting is 1 Single System Set for single if the 1812 is the only unit connected to the phone line or set to multiple if more than one 1812 is connected to the phone line 1 Press 6 1...

Страница 25: ...Talk time can be set from 10 seconds up to 255 seconds 4 minutes 15 seconds and is entered as a three digit number For example to set a talk time of 30 seconds enter 030 in step 2 1 Press 0 8 and ente...

Страница 26: ...e relay will activate and remain activated until commanded to deactivate 3 rd Digit Deactivate relay 4 th Digit Hold open 1 hour The relay will activate for 1 hour and then deactivate itself 2 2 9 Ans...

Страница 27: ...12 Once communication with the visitor is established access can be granted or denied If access is granted press the number to open the door or gate the 1812 will automatically switch the call back to...

Страница 28: ...ne for you and no additional adjustments may be necessary If adjustments are made you will need to do a call forward test call after each adjustment to determine if the result is to your liking The va...

Страница 29: ...eat steps 2 and 3 to enter additional numbers 5 Press 0 TOGETHER to end 0 beeeeeep 2 3 2 Delete Phone Number from Directory Codes 24 50 This programming sequence deletes individual directory code dial...

Страница 30: ...ied It also allows programming of the access codes to momentarily activate a relay or to hold latch a relay 1 Press 7 0 and enter the MASTER CODE 7 0 _ _ _ _ beep 2 Press 2 2 beep 3 Enter a five digit...

Страница 31: ...is always deny access time zone 1 allows 24 7 access for relay 1 only time zone 2 allows 24 7 access for relay 2 only Time zones 3 4 5 and 6 are time zones that have been programmed in 2 5 6 7 Press...

Страница 32: ...AM 1 3 3 _ _ _ _ beep 2 1 1 3 0 beep 3 0 beep 4 0 2 1 4 0 9 beep 5 7 beep 6 0 beeeeeep 2 5 2 Call Forward Time This programming sequence turns the call forward feature either ON or OFF and sets up a s...

Страница 33: ...AM on certain days of the week or all seven days Once the DND schedule has been programmed it can be turned on or off as needed 1 Press 3 4 and enter the MASTER CODE 3 4 _ _ _ _ beep 2 Press 0 to tur...

Страница 34: ...is desired 4 Enter the begin time hour 01 12 and minutes 01 59 then press _ _ _ _ beep 5 Press 0 for AM OR press 1 for PM _ beep 6 Enter the end time hour 01 12 and minutes 01 59 then press _ _ _ _ b...

Страница 35: ...schedule and only ON OFF is desired 4 Enter the begin time hour 01 12 and minutes 01 59 then press _ _ _ _ beep 5 Press 0 for AM OR press 1 for PM _ beep 6 Enter the end time hour 01 12 and minutes 0...

Страница 36: ...or each of the programming parameters WARNING Once started this sequence will program all values to factory default 1 Press 9 0 and enter the MASTER CODE 9 0 _ _ _ _ beep 2 Press 9 9 9 9 then press 9...

Страница 37: ...volume rotate the potentiometer counter clockwise Microphone Gain The microphone gain potentiometer is labeled MIC VOL on the control board This adjustment increases or decreases the loudness in the t...

Страница 38: ...Page 38 1812 161 E 1 10...

Страница 39: ...feature is turned off the 1812 will always ring the resident phones when the Push To Call button is pressed If the call forwarding feature is turned on and the current time does not fall within the ca...

Страница 40: ...e been programmed to activate section 2 4 1 and 2 4 2 Access codes may also be time zone restricted section 2 5 6 To use an access code you must press the key first When a valid access code is entered...

Страница 41: ...y Activation The 1812 system relays can be activated from a remote off site location Be sure that the ability for the 1812 to answer an incoming call has not been disabled see 2 2 9 Refer to the tone...

Страница 42: ...the resident s house perform the following steps 1 Pick up your telephone and press 7 7 beep 2 Enter the desired tone open number 2 2 8 _ beep 3 Hang up 4 2 4 Relay Activation Check The 1812 can be ca...

Страница 43: ...cannot be corrected contact your authorized DoorKing dealer for assistance Before performing any troubleshooting check the following 1 Have a good VOM meter handy to check voltages and continuity 2 H...

Страница 44: ...If the meter shows a negative voltage needle moves off scale to the left reverse the wires Repeat this process to check other wire pairs on bypass switch and 1812 terminal strip Dashed lines are exis...

Страница 45: ...the loose PHON OUT wires The wires should be dead and you should not have any dial tone on these wires If you do have dial tone the 1812 is wired incorrectly Disconnect power immediately and refer to...

Страница 46: ...e noise is still present bad PHON IN or PHON OUT wires Remove 16 VAC wires from the terminal strip Check house phones If noise goes away 16 VAC wires are probably grounded Replace wires Check internal...

Страница 47: ...umber of rings to answer Electric strike locks on or gate operator holds open Excessive voltage drop on 16 VAC line Hold open schedule is enabled Turn off hold open schedule or reprogram time zone Acc...

Страница 48: ...1 2 3 4 5 6 7 8 ON MODEM TCP ENB SW 1 Red White Green Yellow Red White White Gray Orange Purple White DOORKING INC INGLEWOOD CA 90301 Date Dwg No Rev Title 1 09 A M1812P 001 1812 Plus and 1812 Access...

Страница 49: ...200 046 Telephone Test Set Includes clips cord and carrying case P N 1800 050 Battery 12 volt 8 amp hour gel cell provides stand by power during power interruptions P N 1801 008 Postal Lock Box Provid...

Страница 50: ...ay 1 Relay 2 Momentary Activation Hold Release Hold 1 Hour Call Forward Schedule Begin Time Do Not Disturb Schedule End Time Days of Week Begin Time End Time Days of Week Access Code Time Zone Schedul...

Страница 51: ...Directory Codes Dial Out Phone Numbers Directory Code Name Phone Number 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1812 161 E 1 10 Page 51...

Страница 52: ...Access Code Log Sheet Name Access Code Time Zone Schedule Number Relay Momentary or Hold Page 52 1812 161 E 1 10...

Страница 53: ...1812 161 E 1 10 Page 53...

Отзывы: