Wiring
Wiring methods used shall be in accordance
with National Electrical Code, ANSI/NFPA 70.
Permissible wire sizes for the terminals (12-26 AWG).
1812 Plus and
1812 Classic
Removable
Terminal
1812 Plus and
1812 Classic
Removable
Terminal
1802/1803/1808/1810
Entry System Terminal
1802/1803/1808/1810
Entry System Terminal
PH LINE
A
B
16VAC
16VAC
E GND
OFF
ON
1801-010
PH LINE
PH LINE
PH LINE
SIM ID: XXXXX
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3 - Ground
2 - Phone In (Positive-Tip)
1 - Phone In (Negative-Ring)
Earth
Ground
Ground
The
EARTH GROUND
must be connected to
a proper ground close by (ground rod, cold
water pipe in the ground, existing electrical
ground, etc.) indicated by dashed lines.
Circuit Board
LED Power
Cellular Power
Cellular
Power
Switch
Power
Icon
SIM
Status
Not Used
Signal
Strength
Twisted Pair Phone
Line
MUST
be used.
Twisted Pair Phone
Line
MUST
be used.
Twisted Pair
Phone Line
MUST
be used.
Cellular Module
Removable
Antenna
POWER
Choose Terminal
Connection
for
SYSTEM A
1800
Voice ONLY Cellular System
Choose Terminal Connection
for
SYSTEM B
1800 “Optional”
2 - Phone In (Positive-Tip)
1 - Phone In (Negative-Ring)
TWO Entry Systems -
The Voice ONLY cellular
system can supply telephone service for
TWO
1800s
designated as
System A
and
System B
.
The telephone line is
SHARED
with both 1800s.
Each 1800
MUST
be programmed for
Multiple
Systems
, see specific 1800 Installation/Owner’s
instruction manual for more information.
DKS Cellular Server
hosted by AT&T cellular network with
DKS Online Registration Completed
SYSTEM A
SYSTEM B
SYSTEM A
SYSTEM B
Do Not Connect Power
To A Receptacle
Controlled By A
ON/OFF Switch.
System B Phone Line Alternate Use
-
If system B is not being used for a
second phone entry system, a phone
can be installed and used. It shares
the phone line with the System A
phone entry system. The phone
cannot be used while a transaction is
taking place on System A.
Power wire polarity
does not matter.
16.5VAC
40 VA
Supplied
Power
Transformer
LED on
Enclosure
Door
LED on Enclosure Door
“AC power
ON
” indicator
Type of wiring to be used on ALL external devices:
A)
Type
CL2
,
CL2P
,
CL2R
, or
CL2X
.
B)
Other cable with
equivalent
or
better
electrical,
mechanical, and flammability ratings.
CELLULAR MODULE LEDs:
Signal Strength Bars:
Blue - More bars, more signal strength.
Bars only display when call is being made.
SIM Status
- Red blinking (error, usually NO SIM)
POWER Icon
- ON (has power)
Note:
Older Model Circuit Boards can be upgraded for
better DTMF tone distortion.
1812 Plus 1971-010 board Rev S or higher.
1812 Classic 1871-010 board Rev AC or higher.
1802/1803/1808/1810 1862-010 board Rev P or higher.
3
1801-065 Issued 1-19
Version B