DoorHan Swing-2500 Скачать руководство пользователя страница 9

9

eMerGency release OperatIOn

unlock

unlock

Lock

Lock

5. emergenCy release operation

Emergency release is used to release the motor in case of power cut. To release the motor, turn the handle by 90 degrees.

Warning! 

Before releasing (linking) the operator, disconnect power supply.

Warning! 

After the operator was installed check the emergency release for correct operation. use of the release may 

cause uncontrolled movement of the driven part due to mechanical failures or an out-of-balance condition.

6. maintenanCe

 

The Swing-2500 automatic system does not require any special servicing.

 

Repairs may be carried out only by a qualified technician trained and certified at an authorized DoorHan centre.

 

 Be sure that after completion of installation the installer has shown the user how to release the door in case of emergency 
and has given instructions on proper operation and maintenance of the automated system.

 

When carrying out maintenance, it is recommended to use DoorHan original spare parts.

 

carry out maintenance of the automatic system at least every six months.

 

Regularly check if the door is properly balanced and moves smoothly when automatically operated.

 

 Regularly check if the extreme positions of door travel are properly adjusted and safety devices are in good working 
condition.

 

 In case of power failure you may need to restore operator’s settings. Once the power supply is restored, check the 
automatic system for proper operation. If the operator settings have changed reprogram them following the instructions 
given in the corresponding paragraph of this manual (pay special warning to Operation time programming).

 

In case of power failure the door will stop. As soon as power supply is restored you can control the operator as usual.

 

After expiration of life time, the item shall be delivered in a specialized disposal point!

 

 

 

If you have lost this Manual, you may request for the duplicate copy to the following address: Kralovsky VRcH 2018, 
Kadan, 43201, czech Republic, or by e mail: [email protected].

 

 The producer (DoorHan) does not supervise the installation of operators, or carry out their maintenance, thus DoorHan 
cannot be held liable for safety of installation, operation and maintenance of the equipment.

7.  troUBleshooting

symptom

possible reason

solution

Operator does not run

power is off

Make sure, that the power is on

Obstruction at gate’s movement

Remove the obstruction

Bad wiring connection

check reliability of electric wiring connection

Operator is released

Engage the operator

Operator stops suddenly

Thermal protection is active

Let the operator cool

The gate does not open or close completely

Wrong operator programming

Reprogram the operator

Содержание Swing-2500

Страница 1: ...r SWING 2500 DoorHan 2014 Installation and Operating Manual 2 3 3 5 5 9 9 9 contents General Information Safety instructions Operator unit Installation emergency Release Operation maintenance Troubles...

Страница 2: ...ecifications 3 1 2 Operator package 3 2 Safety instructions 3 3 Operator Unit 5 4 INSTALLATION 5 4 1 Tools 5 4 2 Installation layout 6 4 3 Installation dimensions 6 4 4 Operator installation 7 5 EMERG...

Страница 3: ...ator Swing 2500 is intended for automation of a street double leaf swinging gate with a load bearing structure The body of the operator which consists of two silumin parts houses a motor a reducer and...

Страница 4: ...ible for unstable work of the automatic system when using safety devices and accessories which are produced by other manufactures without agreement with DoorHan Never leave the electric motors in rele...

Страница 5: ...d and cross screwdrivers 3 Set of drills for metal 4 Set of drills for concrete 5 Pliers 6 Hacksaw for metal 7 Electric drill 8 Tape measure folding rule 1 2 3 4 5 1 Motor 2 Power cable 3 Rear fasteni...

Страница 6: ...es and moving parts of the door In case of supply cable damage use the suitable type of the cable Cables needed for installation of Swing 2500 operator and accessories if available Cable 2 0 5 mm2 pho...

Страница 7: ...lts should be screwed between the bricks When fastening to a concrete pole use anchor bolts as shown in the picture below 4 4 operator installation warning Before installation make sure that the gate...

Страница 8: ...opening parameters and is adjusted during installation Fastening angle of rear bracket 98 mm 90 mm 95 mm 78 mm 68 mm 40 mm 28 mm Fastening angle of front bracket 158 mm 145 mm 55 mm 60 mm 155 mm 60 m...

Страница 9: ...usted and safety devices are in good working condition In case of power failure you may need to restore operator s settings Once the power supply is restored check the automatic system for proper oper...

Страница 10: ...Notes...

Страница 11: ...Notes...

Страница 12: ...our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Rep...

Отзывы: