9
A setting will be stored only when you program the UPPER door position. The upper position shall be programmed before
setting of the lower door position.
A setting will be stored only when you program the LOWER door position.
UPPER DOOR POSITION
S
P
+
-
S
P
+
-
S
P
+
-
S
P
+
-
S
P
+
-
Press and hold
the key “P” for
about 5 sec
After the sound
signal you’ll see “1”
on the display
Press “P”, the “1”
will blink
Pressing “+” for opening or “–“ for closing of the door, put the leaf in
the required opening position and press the “P” for storing
Press the “P” and
the “2” will blink
Pressing “+” for opening or “–“ for closing of the door, put the leaf in
the required closing position and press the “P” for storing
Press the “–“ and
the “3” will light
The leaf will move
up automatically
After the door stops in open position, press the “P”, press the “P” again
and the leaf will start to close, after it stops, press the “P” for storing
Press the “P” and
the “3” will blink
Press the “–”
The “2” will light
After the automatic force setup is performed, programming can be completed, as all other parameters have factory settings. To
finish programming, pressing the “+”, select the menu “1”, press “P” and hold it unless the “0” appears on the display.
The operator has a default setting of sensitivity level 4. Usually the user doesn’t need to change this setting.
AUTOMATIC FORCE SETUP
FORCE LIMIT SETUP
Press the “P” and
the “2” will blink
Pressing “+” for opening or “–“ for closing of the door, put the leaf in
the required closing position and press the “P” for storing
Press the “–“ and
the “3” will light
The leaf will move
up automatically
After the door stops in open position, press the “P”, press the “P” again
and the leaf will start to close, after it stops, press the “P” for storing
Press the “P” and
the “3” will blink
Press the “–”
The “2” will light
Factory setting
From low to high sensitivity
You should press
“P” to store the
information
Door operation can fail, if the set
sensitivity is too high.
Press the “–”
“4” will light up, you
should press “P”
again
By pressing “–”,
you should set
the required sensitivity
on the assumption that
the more dots are
displayed, the less
force sensitivity
Нажмите «–» —
загорится «5»
Нажмите «P»
Нажмите «+»
для круглой кнопки,
«–» для прямой
Нажмите «P» для
сохранения
информации
Preparation
Block the carriage.
Turn on power, the indicator of the operator will light, sound signal will be heard.
If programming has not been completed, the settings will not be stored. If there is a mistake in one of the settings, you can
turn off power and reprogram.
ELECTRICAL CONNECTIONS
Содержание Sectional-500
Страница 19: ...19 FOR NOTES...