8
ELECTRIACAL CONNECTIONS
1.2. ACCESSORIES WIRING DIAGRAMS
Type
Colour
Jack
Terminals
Connecting devices
№
Meaning
Control devices
Green
ХP9
1
Open
Full opening command. After closing of contacts of the device connected to
this terminal, the control unit will trigger either full opening of the door or
stepped control of operator (depending on the preset control logic)
2
Close
Close command. After closing of contacts of the device connected to this
terminal, the control unit will trigger door closing
3
Com
Common contact
Safety devices
Orange
ХP7
1
STOP
Stop command. After breaking of contacts of the device connected to this
terminal, the control unit will stop door movement
2
PH CL
Contacts for safety device connection (NC). Safety devices are used to prevent
people, animals and foreign objects from being jammed in the door opening
by the moving door leaf. Activation of safety devices immediately stops or
reverses the door. If the door is open and the sensors connected to these
terminals are triggered, this will prevent any movement of the door
3
COM
Common contact
Connection of limit
switches
Blue
ХP3
1
SW CL
Connection of limit switch regulating down travel limit (limit switch red wire)
2
SW OP
Connection of limit switch regulating up travel limit (limit switch green wire)
3
COM
Common contact (limit switch white wire)
Contacts of
accessories power
White
ХP8
1
(-)
Unstable voltage 24 V
2
+
Additional accessories
Yellow
ХP6
1
LAMP
Signal lamp (~ 220 V) terminals are available on pcb 1.1 only
2
Power of motor
Grey
ХP2
1
N
Electric motor common terminal
2
L1
Electric motor closing terminal
3
L2
Electric motor opening terminal
Power of board
Red
ХP1
1
N
Mains supply (~ 220 V) connection
2
L
Table 2.
Control unit terminals
Fig. 2.
Wiring diagram of 3-button control station, photocells and wicket door sensor
Содержание PCB-SH
Страница 2: ...2 1 1 1 STOP PHCL COM Program SW OP SW CL OP CL PH CL STOP STOP Remote CODE 1 1...