background image

OPERATOR INSTALLATION

7

1.  Microswitch
2.  Motor shaft
3.  Splined bushing
4.  Guide
5.  U-bracket
6.  6 x 15 self-drilling screws

NON-STANDARD INSTALLATION

1.  When doing a non-standard installation of the operator (at an angle of 90°). the microswitch.must be moved to a special 

place. To do this:

 

a)   Disconnect the bottom cover of the housing and disconnect the microswitch contact of the board.

 

b)   Disconnect the microswitch of the top housing cover.

 

c)   Squeeze in the new microswitch location the plug out of the hole and pull through it the microswitch contact and connect 

it to the board.

 

d)   Secure the microswitch (1) on the top housing cover with the help of self-drilling screws.

 

e)   Mount the body of the operator.

2.  Install the splined bushing (3) on the motor shaft (2).
3.  Insert the motor (2) in the guide hole (4).
4.  Secure the motor by means of U-brackets (5) and self-drilling screws (6). 

2

3

4

5

6

1

Содержание FAST-750

Страница 1: ...rating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION ELECTRICAL CONNECTIONS OPERATOR PROGRAMMING REMOTE CONTROL PROGRAMMING MANUAL OPENING MAINTENANCE TROUBLESHOOTING 2 2 4 5 6 9 10 13 14 15 15 Actual versions soft v 1 0 pcb v 1 0 ...

Страница 2: ...ifications 3 1 2 Operator package 3 1 3 Track 4 2 SAFETY INSTRUCTIONS 4 3 OPERATOR UNIT 5 4 OPERATOR INSTALLATION 6 4 1 Tools 6 4 2 Requirments to door installation 6 4 3 Connection of operator and guide 6 4 4 Track installation 8 5 ELECTRICAL CONNECTIONS 9 5 1 Сontrol block technical specifications 9 5 2 Сontrol block wiring diagram 9 5 3 Photocell installation option 10 6 OPERATOR PROGRAMMING 10...

Страница 3: ... it and check that the operator is not damaged If any damages are found contact the operator supplier The operator components included in the standard package are listed in the following table ПРИВОД SECTIONAL 750 1200 FAST 750 DoorHan 2012 Инструкция по монтажу и эксплуатации СОДЕРЖАНИЕ ОБЩИЕ СВЕДЕНИЯ ПРАВИЛА БЕЗОПАСНОСТИ УСТРОЙСТВО ПРИВОДА УСТАНОВКА ЭЛЕКТРИЧЕСКИЕ ПОДКЛЮЧЕНИЯ ПРОГРАММИРОВАНИЕ ПРИ...

Страница 4: ...ble support when working at height The operator is allowed to install at more than 2 5 m height You should use hand and face protection when drilling holes You should use metal goods from the operator package or other goods equivalent to them for fastening the product You should power off when performing installation cleaning or maintenance of the operator When mounting the operator on doors with ...

Страница 5: ... For safe and correct work of the operator it is necessary to install a mechanical stop to limit the door leaf motion WARNING RISK OF INJURY Have a qualified technician lay the cables 230 V AC The cables must be laid in protective corrugated tubes In case of supply cable damage use the suitable type of the cable Cables needed for installation of Sectional 750 1000 1200 Fast 750 operator and access...

Страница 6: ...t of the guide rail when the door is completely closed pic 2 4 3 Connection of operator and guide 1 Motor shaft 2 Bushing 3 Guide 4 U bracket 5 Tapping screws 1 Put the operator bushing 4 on the shaft 5 2 Insert the operator unit into the hole on the guide 3 3 Fasten the operator with U brackets 2 and tapping screws 1 Pic 1 Pic 2 45 мм 4 OPERATORINSTALLATION 1 Set of spanners 2 Set of slotted and ...

Страница 7: ...onnect the microswitch contact of the board b Disconnect the microswitch of the top housing cover c Squeeze in the new microswitch location the plug out of the hole and pull through it the microswitch contact and connect it to the board d Secure the microswitch 1 on the top housing cover with the help of self drilling screws e Mount the body of the operator 2 Install the splined bushing 3 on the m...

Страница 8: ...lf tapping screws 2 Fig 5 1 4 You should fasten the track 3 and the lintel mounting bracket by means of a track fixation bolt 4 Fig 5 3 5 You should install a U shaped bracket 5 on the track approximately at a distance 2 3 L and attach it to the ceiling Fig 5 4 6 You should install track mounting brackets 6 on the track approximately at a distance 1 3 L and attach them to the ceiling Fig 5 5 7 You...

Страница 9: ...а Sr F2 5a 5 ELECTRICAL CONNECTIONS 5 1 Сontrol block technical specifications 5 2 Control block wiring diagram WARNING The cable wires must be protected from contact with any rough or sharp parts All connections shall be made only when power is off PE 12V ANT GND IR GND 24V NO NC COM COM NO NC DOOR STOP Antenna Emergency stop button To lightening lamp built in operator housing Supply voltage of m...

Страница 10: ... lens of the receiver in order to increase its sensitivity Avoid direct sunlight Select the desired mode of the photocells with respect to the control contacts NO normally open or NC normally closed If necessary change the jumper position NO NC For steady work the maximum distance between the photocells must not exceed 25 m In bad weather fog rain etc the coverage may be reduced by 30 OPERATIONAL ...

Страница 11: ...nge these settings Press P to save the information Press P to save the information After finishing the automatic force setup a beep will sound and the program comes out of programming mode automatically After performing these setups the programming can be finished all other parameters have factory settings When pressing and select an operator force function value 1 minimum force value 6 maximum fo...

Страница 12: ...the information When pressing and select a function value 0 off 1 on Press 8 will light When entering the 5th point of menu two digits will be displayed sequentially After having displayed the digits the program returns to main menu The first digit tens the second digit units The value received is multiplied by 1000 to receive information on amount of cycles driven by the operator The 2nd digit wi...

Страница 13: ... to press and hold the button 1 of the remote control 3 Release the buttons pressed 4 Press the remote control button already set up 5 On the new remote control select a button with the help of which you will control the operator s work and press it twice A beep will sound NOTE It is possible to add all four control buttons into the operator To delete the remote controls from the receiver memory p...

Страница 14: ... operator can be switched to manual control To do this pull down the releasing device cord The carriage should withdraw from the engagement amd after that the door can be operated manually Fig 7 When main power is restored When main power is restored the operator is to be set to automatic control To do this move the carriage into the locked position by pulling the releasing device cord to youself ...

Страница 15: ...ain 10 TROUBLESHOOTING 9 MAINTENANCE The Sectional 750 1000 1200 Fast 750 automatic system does not require any special servicing Repairs may be carried out only by a qualified technician trained and certified at an authorized DoorHan centre Be sure that after completion of installation the installer has shown the user how to release the door in case of emergency and has given instructions on prop...

Страница 16: ... a guide and inspect it Make sure that the guide is not damaged If you have found any damages please contact the supplier 2 Disassemble a chain tensioner mechanism pos 1 Fig 1 3 Unfasten screws of a sprocket holder pos 2 Fig 2 4 Remove a chain with a carriage mechanism pos 3 Fig 3 ...

Страница 17: ...ENDIX 1 17 Figure 4 Figure 5 4 5 Disassemble a support pos 4 into two parts Fig 4 6 Cut the guide and shorten the chain to the required dimensions Fig 5 7 After cutting assemble the guide in reverse order ...

Страница 18: ... our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Republic Telephone 420 474 319 111 E mail europe doorhan com www doorhan cz ...

Отзывы: