INSTALLATION 

 

 

Remove the back cover from the unit 

 

Drill 2 holes (A,C) on the wall for the screws and one hole for the cable 

 

Knock the supplied rubber bungs to the screw holes (A,C) 

 

Fix the back cover firmly on the wall with 4 flat head screws 

 

Thread the cable through the cable hole (B) 

 

Attach the unit to the back cover 

                         

             

                       

 
Wiring cable

 

Wire Insulation Colour 

Function 

Notes 

Red 

AC & DC 

12-24V DC / 12-18V AC Regulated Power Input

 

Black 

AC & DC 

12-24V DC / 12-18V AC Regulated Power Input 

Grey & Black 

GND 

Negative Pole 

Blue 

NO1 

Normally Open Relay 1 output 

White 

COM1 

Common Connection for Relay 1 Output 

Green 

NC1 

Normally Closed Relay 1 Output 

Yellow 

OPEN1 

Request to Exit input 1 

                                                   

Advanced Input and Output Features – Relay 2 

Blue & Black 

NO2 

Normally Open Relay 2 Output 

White & Black 

COM2 

Common Connection for Relay 2 Output 

Green & Black   

NC2 

Normally Closed Relay 2 Output 

Yellow & Black 

OPEN2 

Request to Exit input 2   

Grey 

Alarm - 

Alarm Negative   

Brown 

D_IN 

Door Status Detecting   

 

 
 
 
 
 
 
 
 
 

Doorentryonline 

Ltd

Содержание K401-E

Страница 1: ...K401 E External Stand Alone Keypad Proximity Card Reader User Manual D o o r e n t r y o n l i n e L t d ...

Страница 2: ... etc The K401 E has many extra features including block enrollment anti tamper alarm backlit keypad buttons These features make the K401 E an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories warehouses laboratories banks and prisons Features Weather resistant to IP66 Strong Zinc Alloy Electroplated a...

Страница 3: ... Standard Proximity Card 25mm 35mm Wiring Connections Electric Lock Exit Button DOTL External Alarm Door Bell Relay Adjustable Relay Output Time Adjustable Alarm Output Time Lock Output Load Alarm Output Load Two NO NC COM 1 99 Seconds 5 seconds default 1 3 minutes 1 minute default 3 Amp Maximum 3 Amp Maximum Environment Operating Temperature Operating Humidity IP66 30 60 or 22 F 140 F 10 90 Non C...

Страница 4: ... Regulated Power Input Black AC DC 12 24V DC 12 18V AC Regulated Power Input Grey Black GND Negative Pole Blue NO1 Normally Open Relay 1 output White COM1 Common Connection for Relay 1 Output Green NC1 Normally Closed Relay 1 Output Yellow OPEN1 Request to Exit input 1 Advanced Input and Output Features Relay 2 Blue Black NO2 Normally Open Relay 2 Output White Black COM2 Common Connection for Rela...

Страница 5: ...o gate controller using Normally Open contact Comments Relay 2 can be used to operate a doorbell if there is no need to operate a second door The wiring to connect the doorbell is via NO2 and COM2 Press the K401 E will send out a switching signal to the doorbell as long as you press the the doorbell will operate it will stop when you release the D o o r e n t r y o n l i n e L t d ...

Страница 6: ...elete Card to allow rapid card enrollment They are for Relay 1 only Anti Tamper Alarm The K401 E uses an LDR light dependent resistor as an anti tamper alarm If the keypad facia is removed the tamper alarm will operate PROGRAMMING Configure the Keypad Change the configure settings according to your application optional Multiple configuration settings can be changed at one time Enter program mode c...

Страница 7: ... be entered Note When adding users if the card fob or Pin user has been enrolled already you can not add it again on the same relay or the device will give a bleep as an error It is ok to enroll the same card fob or PIN for both relay outputs Factory default setting Card or PIN mode To set users for Relay 1 4 1 0 To add PIN users 1 User ID number PIN The ID number is any number from 1 1000 The PIN...

Страница 8: ...1 1000 To delete Card users by cards Note Users can be deleted continuously without exiting programming mode 3 Read Card The device can automatically identify the card of relay 1 or relay 2 To delete Card users by user ID This option can be used when a user has lost their card 3 Enter the User ID To delete card users by card number 9 Input 8 digits or 10 digits Card number Cards can be deleted con...

Страница 9: ...outside programming mode so the user can undertake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 3 Read Card or 3 User ID To set users for relay 2 4 2 1 The operation is the same as relay 1 To set Card user only in this mode users can only be valid by card or fob To set Card user only 4 1 2 Relay 1 4 2 2 Relay 2 Entry is by Card fob only Relay...

Страница 10: ...minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes depending on the option selected below Normal status No keypad lockout or alarm 7 0 Default Keypad Lockout 7 1 Alarm Output 7 2 Alarm output time To set the alarm output time 8 1 3 Default is 1 minute 1 3 minutes available Acoustic Signal The acoustic signal can be set on or off When on the keypad ...

Страница 11: ... Cards have been lost 1 Power down the K401 E 2 Press the Star button and hold at the same time power up the keypad 3 Release the button and wait until the amber LED shines Parts 4 5 must be undertaken within 10 seconds 4 Present any 125KHz proximity EM card or the Master Add Card provided to the K401 E This card is now the Master Add Card 5 Present any 125KHz proximity EM card or the Master Delet...

Страница 12: ... for Relay 1 ON Short Single Bleep Entry Granted for Relay 2 ON Alarm Mode Engaged Flashing Alarm K401 E Simplified Instruction Function Description Operation Enter the Programming Mode Master Code 666666 is the default factory master code Change the Master Code 0 New Master Code Repeat New Master Code code 4 6 digits Add Card User 1 Read Card for relay 1 2 Read Card for relay 2 Add PIN User 1 Use...

Отзывы: