background image

Reset Procedure

 

Reset Alarm: 

The alarm will sound for 3 minutes. To reset, present a valid user card or enter 

* (Master Code) # 

via the 

remote control

 

 
 
Reset to Factory Default: 

To reset to factory default, power off, press the Exit Button or short circuit the Black (GND) and Yellow (Open) 
wires, and then power on, there will be two bleeps, and the LED light will turn orange, keep this condition until 
you hear a long bleep after 10 seconds. The LED will turn red to confirm factory default is successful   
 

 
Reset to Factory Default to add new Mater Cards: 

To reset to factory default, power off, press the Exit Button, or short circuit the Black (GND) and Yellow (Open) 
wires, and then power on, there will be two bleeps, and the LED light will turn orange   
 
Release the exit button or the Black (GND) and Yellow (Open) wires, then present any two 125KHz EM cards or 
key fobs and the LED will turn red to confirm factory default is successful   
The first card presented will be the 

Master Add Card

, and the second card will be the 

Master Delete Card

 

 

Note:

 Reset to factory default, the user’s card/key fob information is still retained   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание DEO-SR2

Страница 1: ...DEO SR2 Proximity Wiegand Card Reader with Remote Control User Manual...

Страница 2: ...Reads 125KHz EM HID card or key fob One programmable relay operation Pulse mode Latch mode relay operation Remote infrared programmer Master Add Master Delete cards 1000 users 998 common users 2 panic...

Страница 3: ...Package Contents SR2 Card Reader Infrared Remote Control Manager Cards 10 user cards or key fobs Diode IN4004 For relay circuit protection Self Tapping Screws 3 25mm Wall Anchors Screw Driver...

Страница 4: ...it to the back cover Wiring cable Wire Insulation Colour Function Notes Red Power AC1 12 24 Volts AC DC Power input Black GND Ground Pink AC2 12 24 Volts AC power input Blue NO Normally open relay out...

Страница 5: ...for lock release Fail secure power to unlock Common power supply for auto gate controller using Normally Open contact Attention Install a 1N4004 or equivalent diode across the locking device when usin...

Страница 6: ...ration Master Code 72 is factory default for stand alone 73 4 Exit Program Mode User data transfer connection 1 x power supply and 9 x SR2 units Set User Data Transfer Programming Step Remote Control...

Страница 7: ...try standard 26 bit EM and HID Proximity card or key fob Master Add Card Master Delete Card Easy way Page 10 Sound and Light indications Operation Status Led Colour Buzzer Stand by Red light bright En...

Страница 8: ...Operation 1 Enter Program Mode Master Code 2 Add Card Using Auto ID number Allows the SR2 to assign Card to next available User ID number OR 3 Add Card Select Specific ID number Allows manager to defi...

Страница 9: ...output relay on activation Programming Step Remote Control Operation 1 Enter Program Mode 2 Pulse Mode OR 3 Latch Mode Master Code 3 1 99 The relay time is 1 99 seconds 1 is 50mS Default is 5 seconds...

Страница 10: ...emote Control Operation 1 Enter Program Mode 2 Read EM HID card OR 3 Read EM card only OR 4 Read HID card only Master Code 93 factory default 94 95 5 Exit Program Mode Add cards by Master Add Card Pro...

Страница 11: ...o confirm factory default is successful Reset to Factory Default to add new Mater Cards To reset to factory default power off press the Exit Button or short circuit the Black GND and Yellow Open wires...

Страница 12: ...the keypad to bleep constantly The unit will also be Blocked from use The function cannot be disabled but it can be stopped by presenting a valid card or key fob to the reader or entering the Master C...

Отзывы: