ENGLISH
11
LAN / POE
D0 D1 GND Wiegand
R1
R1
R2
R2
15 VDC
– +
Port
Description
LAN/POE
T+ T- R+ R-
The device does not have an integrated standarized RJ45 socket to ensure ...
• that the device rests as flat as possible on the wall.
• that no wall needs to be levered up.
• that a strong and inflexible Cat.6 or Cat.7 installation cable can be used.
Use only four wires (1, 2, 3 and 6) of a standard Network cable Cat.5 or better,
coming from the Internet Router/PoE-Switch/PoE-Injector.
Cat.5 / Cat.6 Network cable
T+ White and orange network cable wire (Number 1, Transmit Data +)
T - Orange network cable wire (Number 2, Transmit Data -)
R+ White and green network cable wire (Number 3, Receive Data +)
R - Green network cable wire (Number 6, Receive Data -)
Cat.7 Network cable (Installation cable)
T+ White network cable wire from pair “orange/white”
(Number 1, Transmit Data +)
T- Orange network cable wire from pair “orange/white”
(Number 2, Transmit Data -)
R+ White network cable wire from pair “green/white”
(Number 3, Receive Data +)
R- Green network cable wire from pair “green/white”
(Number 6, Receive Data -)
NOTICE
Do not power the device simultaneously via the power supply from
the power supply unit (mains adapter) and the power supply via PoE.
T+
T-
R+
R-