HOLD OPEN TIME **     

Amount of time that the door remains

open and no other activation is received.

DOOR BRAKING **   

When the door reaches the check

location, the motor is decelerated to halt motion. This parameter

is a hard DECELERATION this is for HEAVY DOORS ONLY.

THIS IS NOT TO BE USED IN CONJUCTION WITH

DECELERATION leave this set to default unless your door is so

heavy that it will not slow for check speed and runs into the stop

or slams shut.

Handing **     

Handing sets the direction polarity of the motor.

When the door is 1st activated and starts the learning cycle we

want the door to travel to the full open position first. If the door 

tries to close first you must change the handing direction.

LOCK TYPE **   

Sets controller to operate either FAIL SAFE or

FAIL SECURE lock

BREAKOUT POLARITY **  

Depending on what type of

switches your door has, either Normally Open or Normally

Closed contacts. If the breakout panels are closed and the

orange LED marked B-Out

(located below connector J7) is illuminated the door cannot be

activated. CHANGE POLARITY.

LOCK DELAY **    

Set to ON if the door has an electric lock.

Delay is for 1 second. When an activation signal is received the

door will be delayed from opening while the lock is being

disengaged.

LOAD FACTORY DEFAULTS **

Pressing the program key will reset a setting to factory

defaults

PLEASE NOTE:   ABOVE ITEMS MARKED WITH ** CAN ONLY BE AJUSTED 
IN PROGRAM MODE.  

To access program mode, Press and hold the 

program button. While the programming button is pressed, press and 
release the reset button then release the programming button. 

After making changes, press RESET to exit program mode. 

The control will perform a learn cycle on the first activation after reset. 

Содержание DC-ONE V3

Страница 1: ...DC ONE V3 AUTOMATIC DOOR CONTROLLER GETTING STARTED AND TROUBLESHOOTING GUIDE...

Страница 2: ...ector K J7 Special Modes Connector L J8 Lock Connector M Test Button activates door N Program Button O Menu Down Button P Menu Up Button Q Reset Button R Lock Voltage Selector 12 24 S Display Intensit...

Страница 3: ...RN OPEN SPEED Adjust speed to allow door to travel just enough to complete the learn cycle If door isn t traveling fast enough It is recommended to adjust Learn Torque first SELECT MOTOR TYPE It is ve...

Страница 4: ...tation CLOSE TORQUE This is where we set the controller power to move the door throughout the entire close cycle If the door will not close properly or moves to slow This is where to start Turn this u...

Страница 5: ...SAFE or FAIL SECURE lock BREAKOUT POLARITY Depending on what type of switches your door has either Normally Open or Normally Closed contacts If the breakout panels are closed and the orange LED marked...

Страница 6: ...er open and closed when the TEST button is pressed Use caution during this test as the sensors will not be operational The following inputs have status LEDs to help identify problems Power Safety Cont...

Страница 7: ...ary Safety beam is blocked or is faulty Correct as necessary Door handing is set incorrectly Enter program mode and change hands Door powers closed and then stay closed Press the TEST button on the fa...

Страница 8: ...m satisfactorily Walk test the door according to AAADM recommended guidelines and correct all discrepancies if any before leaving the job site DO NOT compromise proper performance If repairs cannot be...

Страница 9: ...ctivate during off one way or night mode o Green LED is on when active Activation o Activates the door during all modes o Green LED is on when active Breakout o Stops door motion o Software selectable...

Страница 10: ...N SWITCH WIRING DC ONE V3 Control 5PSW1 5PSW2 5PSW3 5PSW4 J6 x 1 Common x 2 Off x 3 One Way x 4 Partial Open x 5 Hold Open x 6 Reset x 7 24 VAC x 8 24 VAC Return x 9 Common x 10 Safety 1 2 3 4 5 6 x x...

Страница 11: ...Controls for further technical support when needed Door Controls USA Inc 321 VZ County Road 4500 Ben Wheeler TX 75754 Phone 1 800 437 3667 Fax 1 800 356 8858 Email parts doorcontrolsusa com www doorco...

Страница 12: ......

Отзывы: