Door Controls DC-ONE V3 Скачать руководство пользователя страница 4

OPEN DECELERATION

 

When the door reaches the check

open location, the motor is decelerated to halt motion. This

parameter controls the length of time for DECELERATION.  this

is for HEAVY DOORS only. leave this set to default. If you need

to add some deceleration, Raising this value will increase

deceleration “ON” time (Not the amount of deceleration)

CLOSE DECELERATION

  When the door reaches the check

close location, the motor is decelerated to halt motion. This

parameter controls the length of time for DECELERATION this is

for HEAVY DOORS only, leave this set to default. If you need to

add some deceleration, Raising this value will increase

deceleration “ON” time (Not the amount of deceleration)

OPEN TORQUE    

This is where we set the controller power to

move the door throughout the entire open cycle.  If the door will

not open properly or moves to slow. This is where to start. Turn

this up 10% at a time till the door moves through the cycle without

hesitation.

CLOSE TORQUE   

This is where we set the controller power to

move the door throughout the entire close cycle.  If the door will

not close properly or moves to slow. This is where to start. Turn

this up 10% at a time till the door moves through the cycle without

hesitation.

OPEN CHECK TORQUE      

 This is where we set the controller

power to move the door throughout the open check cycle.  If the

door will not open completely. This is where to start. Turn this up

10% at a time till the door moves through the cycle without

hesitation.

CLOSE CHECK TORQUE      

This is where we set the controller

power to move the door throughout the close check cycle.  If the

door will not close completely. This is where to start. Turn this up

10% at a time till the door moves through the cycle without

OPEN CHECK SIZE **     

This is where the door transitions from

Open Speed to Check Speed. (inches from full open position)

CLOSE CHECK SIZE  ** 

This is where the door transitions

from Close Speed to Check Speed. (inches from full closed

position)

REDUCE OPEN SIZE **   

Door will only open to this setting if

Partial Open is selected on Multifunction Switch and an

Activation signal is received.

Содержание DC-ONE V3

Страница 1: ...DC ONE V3 AUTOMATIC DOOR CONTROLLER GETTING STARTED AND TROUBLESHOOTING GUIDE...

Страница 2: ...ector K J7 Special Modes Connector L J8 Lock Connector M Test Button activates door N Program Button O Menu Down Button P Menu Up Button Q Reset Button R Lock Voltage Selector 12 24 S Display Intensit...

Страница 3: ...RN OPEN SPEED Adjust speed to allow door to travel just enough to complete the learn cycle If door isn t traveling fast enough It is recommended to adjust Learn Torque first SELECT MOTOR TYPE It is ve...

Страница 4: ...tation CLOSE TORQUE This is where we set the controller power to move the door throughout the entire close cycle If the door will not close properly or moves to slow This is where to start Turn this u...

Страница 5: ...SAFE or FAIL SECURE lock BREAKOUT POLARITY Depending on what type of switches your door has either Normally Open or Normally Closed contacts If the breakout panels are closed and the orange LED marked...

Страница 6: ...er open and closed when the TEST button is pressed Use caution during this test as the sensors will not be operational The following inputs have status LEDs to help identify problems Power Safety Cont...

Страница 7: ...ary Safety beam is blocked or is faulty Correct as necessary Door handing is set incorrectly Enter program mode and change hands Door powers closed and then stay closed Press the TEST button on the fa...

Страница 8: ...m satisfactorily Walk test the door according to AAADM recommended guidelines and correct all discrepancies if any before leaving the job site DO NOT compromise proper performance If repairs cannot be...

Страница 9: ...ctivate during off one way or night mode o Green LED is on when active Activation o Activates the door during all modes o Green LED is on when active Breakout o Stops door motion o Software selectable...

Страница 10: ...N SWITCH WIRING DC ONE V3 Control 5PSW1 5PSW2 5PSW3 5PSW4 J6 x 1 Common x 2 Off x 3 One Way x 4 Partial Open x 5 Hold Open x 6 Reset x 7 24 VAC x 8 24 VAC Return x 9 Common x 10 Safety 1 2 3 4 5 6 x x...

Страница 11: ...Controls for further technical support when needed Door Controls USA Inc 321 VZ County Road 4500 Ben Wheeler TX 75754 Phone 1 800 437 3667 Fax 1 800 356 8858 Email parts doorcontrolsusa com www doorco...

Страница 12: ......

Отзывы: