Страница 1: ...from your smart phone via the home WIFI It will control single and many multi speed pumps sanitiser heater solar heating lights water features pool spa valve actuators and all spa eguipment reguiremen...
Страница 2: ...C relay contacts when the heater is to be turned on The heater end of the interlock cable connects in series with the heater s pressure flow or fireman s switch Contact the heater manufacturer for the...
Страница 3: ...ed beneath the controller SENSOR NOTES All excess cable must be removed coils of cable are not permitted under any circumstances and must not be tied to 2A0V wiring If the cable is to be extended with...
Страница 4: ...xpansion Unit 1 the connection cable from the master controller will plug in here If Expansion Unit 2 the connection cable runs from here to Expansion unit 1EXP OUT If Expansion Unit 1 the connection...
Страница 5: ...V variable speed pumps may be controlled via the Aquatek speed control function by inserting the control cable wires into the PUMP CONTROL terminal block Colour order from left to right is yellow blac...
Страница 6: ...Green Wire Red Wire Brown Wire PENTAIR VS F None Green Wire Yellow Wire None None DAB None Brown Wire Black Wire None Red Wire INSNRG SUPPLIED BY INSNRG None White Orange Stripe Wire Orange Wire None...
Страница 7: ...on e The light next to Start Stop will be lighted green Pentair VS F Turning Off Priming a Disconnect the RS 485 communication cable from the pump b On the pump control module press Menu and use the A...
Страница 8: ...en the pump and the Aquatek controller and control is automatically instated Reltech Theralux Speck Henden with Fasco Motor Turning Off Priming a Disconnect the pump communication cable from the pump...
Страница 9: ...roller will retrieve the previously saved settings On power up the controller will start automatic pool operation BACK Pressing the BACK button will allow you to go back to previous menu options ENTER...
Страница 10: ...ion ends The timer amounts after the 3 minute backwash are The timer amounts to stop the pump PUMP ON 30 MINS are displayed as follows PUMP ON 1HR HOURS OFF 01HR PUMP ON 2HR HOURS OFF 02HR PUMP ON 3HR...
Страница 11: ...The circulation pump will run between these times for filtration purposes Once you have set the first filter time you will then be asked to select a pump speed for the first filter cycle Note This wi...
Страница 12: ...n display RUN UNTIL ON HEATED OFF Use the or buttons to select which option you would like and press Enter If you select ON the system will utilise the Heat Pump or Gas Heater to continue to heat the...
Страница 13: ...s been completed you can move onto the next allowable appliance Adjust and set as above Notes Socket type Sanitiser is not allowed on appliance timer as it follows filter timer Socket type Filter Time...
Страница 14: ...of lights will be the same colour as chosen for that allocated socket Feature from Solar This feature gives you the ability to be able to utilise an independent solar heating system for a water featur...
Страница 15: ...Appliances can be allocated on up 8 power sockets A valves and 1VF contact Socket 1 2 Valves 1 4 and the VF Contact are all located on the master controller Sockets 3 A 5 are located on Expansion Uni...
Страница 16: ...displayed Use the or buttons to toggle through the range of allowable appliances Press Enter to select Alternatively if you don t want to change any more appliances press the MENU button to exit When...
Страница 17: ...in RPM In the case of the PentairVS F Theralux Reltech and Speck pumps you will set the default speed only as the pump has pre set speeds In the case the DAB brand you will be asked to set the 4 speed...
Страница 18: ...he allowable brands and types are as follows AquaQuip AquaQuip INS Aquatight Spa Electrics Spa Electrics Multi Plus Astral Pool ModLite Jandy Single Colour non branded Press Enter to select the light...
Страница 19: ...R ON HEATING WINTER MODE OFF Use the or buttons to select which option you would like and press Enter Note If you selected None for SOLAR then the above option will not be displayed Once you have pres...
Страница 20: ...endent heaters circulation pump If Gas Heater was selected under VF Contact then the following will be displayed GAS HEATER ON HEATING OFF CONTINUED If you select ON the controller will then display G...
Страница 21: ...T PUMP SWITCH ON AT XXD Use the or buttons to select what temperature you would like the Jet Pump to turn on at and press Enter to accept Note The Temperature range is within a 10 offset from the set...
Страница 22: ...th DA Hours being the default setting This setting is here to ensure that the system will switch back over to filtration mode and to ensure that the spa isn t left running constantly Especially useful...
Страница 23: ...ption you would like the controller will exit you to the Installer Setup menu 6 IWhen you enter this menu option the controller will display IPUMP ON ICALL OFF IIf you select OFF the controller will r...
Страница 24: ...will return you to the Installer Setup menu In this menu option you are able to decide which sensor port belongs to which sensor Pool or Roof When you enter the menu the controller will display TEMPE...
Страница 25: ...and assign it to either EXP 1 if first unit or EXP 2 if second unit and will be displayed as below EXPANSION Enter 6 10 Expansion Unit menu function to increase the amount of Expansion Units that can...
Страница 26: ...location and display LODATIDN ACT Use the or buttons to scroll through the options available and press Enter to accept the option you wish to set The controller will then display AUTD ADJUST DST YES T...
Страница 27: ...em then no network name will be displayed Press the Enter button and the controller will display SEARCH WIFI YES 6 12 NETWORK NO WIFI Use the or buttons to alternate between YES or NO Press Enter to a...
Страница 28: ...roller will not support the follow Symbols Tilde will display instead Backslash will display instead Once you have entered the passcode press Enter and the controller will display CONNECTING TO NETWOR...
Страница 29: ...ary to installed a Wifi range extender at the controllers mounted location If the Aquatek is mounted in a bunker below ground level or inside a shed there may also be reception issues The controller m...
Страница 30: ...tructions Then reset the controller by turning it off on 5 Maximum combined rated output load for the 240V socket s is 9 9Amps 2370 Watts or 14 9Amps 3570Watts as described on the unit B Degree of pro...
Страница 31: ...nstallation that is not in accordance with the manufacturer s instruction may void the warranty Warranty does not include on site labour or travel costs to or from installation site Valves and actuato...