Torit PowerCore, TG 2 to TG 12
18
Optional Equipment
HEPA Afterfilter Installation
The optional HEPA afterfilter is designed to capture small
particulate and is attached to the collectors clean-air
outlet.
1. Turn supply power OFF.
2. Remove the bolts from the top back roof panel.
3. Position the HEPA mounting frame on top of the
clean-air outlet aligning existing hole pattern.
4. Mark and match-drill the front flange holes in the
roof panel using a 0.266-in diameter drill bit.
5. Apply 1/4-in diameter rope-type sealant toward the
inside of bolt pattern.
6. Position the HEPA mounting frame on the top panel
aligning the bolt patterns.
7. Bolt in place using the hardware supplied and the
hardware removed in Step 2.
8. Position HEPA filter on mounting frame and secure
with latches.
9. Reset exhaust damper to fully closed position.
10. Turn collector ON.
11. Adjust airflow using the airflow control damper.
Explosion Vent
Personal injury, death, and/or
property damage can result from
material discharge during venting.
The material discharged during the venting of
an explosion must be safely directed outdoors
away from areas occupied by personnel to
reduce risk of personal injury and/or property
damage.
The risk of personal injury and/or property
damage can be minimized or avoided by
locating vented equipment outside buildings
and away from normally occupied areas.
Explosion vents should be inspected regularly
to confirm physical and operational condition.
Replace any damaged parts immediately.
Standard explosion vents are intended for
outdoor installations only.
Unless otherwise noted, the explosion venting
calculations are based on formulas from NFPA-68 for
outdoor applications only, with no duct or obstructions
on the explosion vent panel.
Contact Donaldson Torit for assistance in calculating
specific venting requirements for equipment.
NFPA 68 can provide guidance on both the frequency of
and appropriate details for inspections.