background image

This manual contains specific precautions related to worker safety. The hazard alert image denotes safety 

related instructions and warnings in this manual. DO NOT install, operate, or perform maintenance on this 

product until you have read and understood the instructions, precautions and warnings contained within 

this manual.

Donaldson™ iCue™ Sensor 

Integrated Gateway 

Installation, Operation and 

Maintenance Manual

IOM R060070 (ENG)

Revision 0

English 

Master Language

Содержание iCue Sensor Integrated Gateway

Страница 1: ...warnings in this manual DO NOT install operate or perform maintenance on this product until you have read and understood the instructions precautions and warnings contained within this manual Donaldso...

Страница 2: ...on com Disclaimers Information in this document is subject to change without notice and does not represent a commitment on the part of the Donaldson Company Inc Donaldson provides this documents as is...

Страница 3: ...Location Considerations 3 Overview 3 Mounting 4 Gateway Electrical Installation 4 Low Pressure P Pneumatic Installation 5 High Pressure Compressed Air Pneumatic Installation 5 Gateway Final Assembly...

Страница 4: ...ct is used Since these factors are uniquely within the user s knowledge and control it is essential the user evaluate the Donaldson products to determine whether the product is fit for the particular...

Страница 5: ...card are provided by Donaldson The SIM card will only work with Donaldson s service and should not be removed Note This manual only covers the installation operation and troubleshooting of the Donald...

Страница 6: ...at is included in the kit There may be situations where additional materials are needed to complete the installation A typical installation will involve the following steps 1 Shut down the dust collec...

Страница 7: ...rom the magnets and mount the device Note Allow 20 minutes for the adhesive to cure prior to mounting the gateway from a metallic surface Flange The gateway and power supply may be mounted using the m...

Страница 8: ...supplied 3 16 in ID translucent blue tubing connect the clean air pressure sense line to the Clean port of the gateway Notice To prevent inaccurate sensor readings it is recommended the tubing is ins...

Страница 9: ...EDs Red Orange Green Verify the Power and iCue Service Connectivity LEDs turn green This may take several minutes Gateway Final Assembly 5 Replacement Parts List Part Number Description R060015 Kit Se...

Страница 10: ...g Input 2 Input Signal 10VDC 20mA max 9 Analog Input 2 Ground 10 Analog Input 3 24VDC Output Max output 25 mA 11 Analog Input 3 Input Signal 10VDC 20mA max 12 Analog Input 3 Ground 13 Analog Input 4 2...

Страница 11: ...iCue application Orange Initializing connection to Donaldson iCue application Red Connection failure Off Not connected to Donaldson iCue application 3 Cellular Strength Green Good connection quality...

Страница 12: ...t Green If Cellular Strength LED is OFF or Red reference troubleshooting for that condition Note it may take up to 5 minutes for the iCue Service Connectivity LED to turn green after the Cellular LED...

Страница 13: ...egrated Gateway The gateway can accommodate up to four 4 analog sensors and two 2 digital inputs Analog Sensors The Donaldson iCue Sensor Integrated Gateway can accommodate analog sensors with a 0 10V...

Страница 14: ...Sensor 4 Wire Sensor The Donaldson iCue Sensor Integrated Gateway can support 2 3 or 4 wire sensors using the following wiring configurations These diagrams are representative of installing an analog...

Страница 15: ...set according to the following position Digital High Switch Digital Low Switch Sensed Stated By Gateway Wiring Diagram Unactuated Switch State Actuated Switch State Jumper Setting Normally Open Conta...

Страница 16: ...on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and recei...

Страница 17: ...st accept any interference including interference that may cause undesired operation of the device Informations concernant l exposition aux frux friti radio RF La puissance de sortie mise par l appare...

Страница 18: ...A3 Donaldson Company Inc Service Notes Date Service Performed Notes...

Страница 19: ...ontact Information Donaldson Company Inc 1400 W 94th Street Bloomington MN 55431 1 833 898 5996 FCC Compliance Statement e g products subject to Part 15 This device complies with Part 15 of the FCC Ru...

Страница 20: ...application including the conditions under which the product is used Since these factors are uniquely within the user s knowledge and control it is essential the user evaluate the products to determi...