COMMISSIONING

  It is a requirement of the Supply of Machinery (Safety) Regulations 2008 to 

provide adequate isolation and emergency stop facilities. Due to the varied 

nature of site installations this cannot be provided by Donaldson but instead 

is the responsibility of the customer.

Before putting the dust collector into service the following items should be checked. 

Similar checks, as appropriate, should be made after any major overhaul.

Commissioning check list

Where applicable, ensure that the collector is securely bolted to the floor.

Ensure dust disposal system is correctly installed.

Ensure all ducting is complete, all detachable panels are in position and fixed 

guards are secure.

When new filter elements are installed it is necessary to reduce the airflow 

through the filter media by partially closing the slide gate.
This way the dust will not penetrate the media and can be cleaned off as 

described above. After the elements are conditioned the slide gate can be 

placed back to its original position.

Ensure collectors are suitably earthed.

Ensure electrical power is available.

Check fan motor for correct rotation and that the full load current is not exceeded. 

(Refer to the fan rotation label located on the fan mounting plate inside the 

clean air chamber).

  Keep clear of inlet opening/rotating impeller whilst performing rotation 

check.

To reverse rotation (single phase power supply):
Follow manufacturer’s instructions on the motor nameplate.
To reverse rotation (three phase power supply):
Turn electrical power OFF at source and switch any two phase wires on either

the motor junction box or the controller input terminals.

Ensure access panel seals are intact, then close and secure the panels.

Ensure the compressed air manifold has sufficient protection for overpressure.

Start the compressor and check that the air supply is maintained at the 

recommended pressure.

Switch on the controller.

  When Delta P cleaning is selected, then the cleaning system will not 

operate until the differential pressure rises above a set value of 80 daPa. 

If any of the above check boxes are not ticked, then the reasons why should be 

investigated. (Refer to fault location table in ‘Maintenance’ section).

Содержание DFPRE 4 Series

Страница 1: ...DFPRE Dust Collectors Series DFPRE 4 INSTALLATION OPERATION AND MAINTENANCE MANUAL Publication DOCAM1216401 GB 0520 MASTER LANGUAGE ENGLISH...

Страница 2: ...Installation Operation and Maintenance manual 2 DFPRE 4 Dust Collectors...

Страница 3: ...oning the collector 10 Compressed air requirements 10 Controller 11 Overload protection 11 Installation check list 11 COMMISSIONING 12 Commissioning check list 12 Start up sequence 13 Shut down sequen...

Страница 4: ...he same dust collector as when combined they can create a violent thermite reaction that would ignite a fire and or explosion 4 Applications having a risk of sparks and fires Where sparks are generate...

Страница 5: ...tenance work Any access to internal classified potentially explosive atmospheres where there may be a risk due to explosion During assembly installation or dismantling of equipment potential ignition...

Страница 6: ...licable equipment connected to the dust collector for example a cyclone should be protected using suitable isolation devices against the transfer of flame and pressure if in the event of an explosion...

Страница 7: ...ty air plenum access door Dust disposal Lifting bracket for units Damper valve Clean air plenum access door Dirty air inlet Compressed air connection Spark trap inspection cover Powerbox Fork lifting...

Страница 8: ...inspection The collector is normally supplied in one piece Depending onyour order the following parts are shipped loose Dust disposal system Silencer Spare parts Hardware and sealant Paint can and br...

Страница 9: ...adequate SWL safe working load must be used Refer to lifting label located adjacent to lifting points for weight of equipment supplied by Donaldson When using the four point lifting method chains or...

Страница 10: ...duce excessively contaminated moisture laden air Location of air intake Avoid locating the air intake in an excessively polluted area and install an adequate air intake filter The compressor air intak...

Страница 11: ...efer to the controller manual Details of standard fan motor supply voltage are given in Table 4 refer to Specification section Overload protection All feeder circuits should be adequately protected wi...

Страница 12: ...ide gate can be placed back to its original position Ensure collectors are suitably earthed Ensure electrical power is available Check fan motor for correct rotation and that the full load current is...

Страница 13: ...ter cartridges casing and discharge hopper To achieve this equipment should be shut down in the following order 1 Stop fan only leaving controller and compressed air supply switched on to allow filter...

Страница 14: ...remove the fine particulate and clean filtered air passes through the cartridge to the clean air chamber and discharges through the clean air outlet At regular intervals governed by the controller eac...

Страница 15: ...urely replaced and resealed prior to collector restart This is a good time to check the dust container for damage which may lead to a dust leak or flame emission in the rare instance of an internal ex...

Страница 16: ...ecification and to ensure the same level of safety only genuine spare parts should be fitted Every care has been taken to avoid the risk of ignition of a flammable atmosphere The measures taken to avo...

Страница 17: ...artridges and in turn lower the differential pressure details of pulse interval settings are provided in the controller manual If the differential pressure exceeds 150 mm WG then the cartridges have r...

Страница 18: ...levels should be investigated and corrected immediately Vibration monitoring is mandatory on category 2G 3G and 2D fan assemblies Annually 1 Remove and clean moisture separator filter element 2 Remov...

Страница 19: ...sembly Do not overtighten pipe connections Refer also to figure 9 1 Switch off the compressed air 2 Open the clean air access door 3 Using screwdriver unscrew 4 screws to remove bonnet from valve 4 Di...

Страница 20: ...nt Filter cartridges cannot be washed and re used Do not drop cartridges Refer also to figure 10 1 Turn off power to the collector and compressed air 2 Open Dirty Air Plenum access doors by removing t...

Страница 21: ...ontinue by replacing the remaining filter cartridges in the top row Proceed to replace filter cartridges in the next rows Replacing filter cartridges row by row starting at the top will help limit dus...

Страница 22: ...etal must be removed and disposed of separately Electrical components switches power supplies boards etc must be removed in order to be reused if they are still in good condition or if possible recond...

Страница 23: ...ranspose if necessary Airflow damper incorrectly adjusted Check airflow in duct Adjust damper control until correct airflow is achieved Access panels open or incorrectly secured Check all access panel...

Страница 24: ...clear Visible effluent in clean air outlet Filter cartridges not properly sealed Check cartridge access covers are seated and seal properly Damaged filter cartridge Damaged cartridges can be identifi...

Страница 25: ...20 to 70 C Manifold volume 7 litres Product of pressure and capacity 49 bar litres Material used for manifold construction Structural hollow section according to EN13445 1 bar 105 Pa TABLE 3 COMPRESSE...

Страница 26: ...D 349 X 349 MM X L 660 MM TRIAGONAL EARTHED 2626827E 000 440 Ultra Web Flame Retardant CARTRIDGE DFE ULTRA WEB FR OD 349 X 349 MM X L 660 MM TRIAGONAL 2626913 000 440 Ultra Web Flame Retardant Earthed...

Страница 27: ...4 OD X 26 L P034311 016 340 Sealable bag for dirty cartridge 2622217 000 440 Fan assembly VCM 403S fan assembly including motor 2 2 kW 230V 400V 50Hz AM0569800 VCM 451S fan assembly including motor 3...

Отзывы: