background image

S

afety Instructions 

 

 

 

Important safety notes

 

Concerning symbols used on the extraction unit and referred 
to within this manual. 

 
Danger 
 

Refers to an immediately impending danger. If the danger is 
not avoided, it could result in death or severe (crippling) 
injury. Please consult the manual when this symbol is 
displayed. 

Warning 

 
Refers to a possibly dangerous situation. If not avoided it 
could result in death or severe injury. Please consult the 
manual when this symbol is displayed. 

Caution 
 

Refers to a possibly harmful situation. If not avoided, 
damage could be caused to the product or something in its 
environment. 

  
Important (Refer to manual) 
 

Refers to handling tip and other particularly useful 
information. This does not signify a dangerous or harmful 
situation. Refer to manual when this symbol is displayed. 
 

Electrical Safety 

The AD Nano has been designed to meet the safety 
requirements of the Low Voltage Directive 2006/95/EC 
(previously numbered 73/23/EEC) 

Warning 

When working with the pump/motor housing open, Live 
230/115 volt mains components are accessible. Ensure that 
the rules and regulations for work on live components are 
always observed.

 

 

 

Important 

To reduce the risk of fire, electric shock or injury: 

1.

 

Always isolate the system from the mains power 
supply before removing the pump/motor access 
panel. 

2.

 

Use only as described in this manual. 

3.

 

Connect the system to a properly grounded outlet. 

 
Dangers to eyes, breathing and skin 

Once used, the filters within the AD Nano system may 
contain a mixture of particulates, some of which may be 
sub-micron size. When the used filters are moved it may 
agitate some of this particulate, which could get into the 
breathing zone and eyes of the operative. Additionally, 
depending on the materials being used, the particulate may 
be an irritant to the skin.  

This unit should not be used on processes with sparks of 
flammable materials or with explosive dusts and gases, 
without implementation of additional precautions. 

 

Caution: When changing used filters always wear a mask, 
safety shoes, goggles and gloves.

 

 

Carbon selection 

Please note that the media within the filter fitted in the AD 
Nano is capable of adsorbing a wide range of organic 
compounds. However, it is the responsibility of the user to 
ensure it is suitable for the particular application it is being 
used on. 

 

BOFA Technical Service 

If problems arises with your AD Nano unit or if it displays a 
fault code, please contact us:  

 

Visit our website at www.bofa.co.uk for on-line help. 

 

Or contact the helpline on 

+44 (0) 1202 699 444

Mon-Fri, 9am-5pm. 
Email[email protected] 

Serial Number 

For future reference, fill in your system details in the space 
provided. The serial number is on the rating label located on 
the side/rear of the unit.  
Serial Number:

 

 

01 

Содержание 30105519-1313

Страница 1: ...AD Nano USER MANUAL V1 May 15...

Страница 2: ...npacking and unit placement 3 01 02 Connecting to power supply Optional interfacing 4 01 Turning extractor on 5 01 02 Important safety notes Safety labels 2 01 02 Cleaning the unit Filter replacement...

Страница 3: ...Overview Mains Isolation Switch Control Panel Lockable Castors Door Latches Combined Filter Combined Filter Lever Pre Filter 01 1...

Страница 4: ...Overview Mains Inlet Signal Cable Inlet Optional Exhaust Outlet Air Outlet Air Inlet 02 1...

Страница 5: ...Overview Main Isolation Switch Company Branding Filter Blocked Filter 75 full System Running Clean 03 1...

Страница 6: ...moving the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filters within the AD Nano...

Страница 7: ...acture Relevant approval markings logos PLEASE NOTE If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning...

Страница 8: ...t should be used and with regard to appropriate safety precautions See Appendix for product weight details Ensure that 500 mm space is available around any vented panels on the extractor to ensure ade...

Страница 9: ...nit should not be connected to the mains The supply cord should only be replaced by a BOFA engineer as an electrical safety test may be required after replacement The AD Nano MUST be connected to a pr...

Страница 10: ...PCB Red cable V Black cable V When the extractor is provided with the correct DC voltage the motor will start and maintain the set flow rate Refer to section 5 for how to set the flow when the DC volt...

Страница 11: ...images below to identify the switch your AD Nano unit uses Powder Coated Version Press the main isolation switch to the On position Refer to section 1 for switch location by depressing the I side of t...

Страница 12: ...prevent build up of dust and overheating of the unit Filter Information A log of filter changes should be maintained by the user The filters require attention when the display shows the configuration...

Страница 13: ...orn when changing filters To remove and replace the pre filter follow the procedure detailed below 1 Isolate the electrical supply to the unit 2 Open the door of the unit 3 Remove the lower pre filter...

Страница 14: ...tured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the material deposited on them For your guidance...

Страница 15: ...l Below 60dB A at typical operating speed Size Metric mm Imperial inches Height 797 31 4 Depth 435 17 2 Width 377 14 9 Filters Filter Type Surface area Weight Efficiency Pre Filter 6 0 m F8 Combined F...

Страница 16: ...Creekmoor industrial Estate Poole Dorset BH17 7DU UK Phone 44 0 1202 699 444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 1 618 205 5007 BOFA International GmbH Sudring 62 D 21...

Отзывы: