Torit PowerCore, Model VH and VL 1-4 through 3-30
Disconnect, fuses, low voltage blower starter, and 1TGS switch are customer-supplied.
Use wiring diagram provided with collector.
Wiring by others
Wiring by factory
Solid-State Timer Typical Wiring Diagram for VH 2-12
Input
105-135V/50 -60Hz/1Ph (standard) or 24VDC (optional)
Output Solenoids
The load is carried and turned ON and OFF by the 200
watt maximum-load-per-output solid-state switch.
Pulse ON Time
Factory set at 100-milliseconds.
Do not adjust pulse ON time
unless the proper test equipment
is available. Too much or too little ON time can
cause shortened filter life.
Pulse OFF Time
Factory set at 15-seconds (VH and VL 2-20 and 3-30 units
are set at 10-seconds), adjustable from 1 to 1.5-second
minimum to maximum 60 to 66-second.
Operating Temperature Range
-20° F to 130° F
Transient Voltage Protection
50 kW transient volts for 20-millisecond duration once
every 20 seconds, 1% duty cycle.
Solenoid Valves
115-V at 19.7 watts each
24VDC @ 18 VA watts
Compressed-Air
Set compressed-air supply at 90-psig.
Do not increase supply pressure
above 100-psig as component
damage can occur.