Engine Air Filtration
•
87
MEDIUM DUST AIR CLEANERS
www.buydonaldson.com
Install the Primary
Filter
Install the new primary filter by
pressing and rotating the filter
clockwise until fully fitted against
the stop.
Fasten the Service
Cover
The “INLET” arrow on
the cover should line up
with the air cleaner inlet.
Do not force the cover
onto the air cleaner. It
should go on easily with
no extra force.
Re-fasten the latches which
secure the cover. Make sure that
latches penetrate the slots in both
the body and the cover.
Reset the Filter
Indicator and Inspect
the Air Cleaner System
If your system has a restriction
indicator, reset the device.
Inspect and torque all clamps,
bolts and connections in the entire
air intake system. Check for holes
in piping, and repair if needed.
Close-up of Filter Stop
9
8
FKB Air Cleaners
Service Instructions
Note: If you perform filter maintenance service on a schedule vs. using service indicators, you may want to write
the service date on the filter end cap.
Note: If the cover does not fit flush to the body, the primary filter is not properly seated in the housing.
Recheck the primary and safety filter installation following the proper installation procedure so they become
fully seated.