11
4.4
Combustion products exhaustion and air intake vertically-arranged coaxial device
ø80-125 (type C
33
) (Only for EV 20/30 HFC)
The combustion products exhaustion and air intake can be carried out through concentric pipes of
Ø80 mm. for the combustion products exhaustion and Ø125 mm. for the air intake, by means of the
vertically-arranged outlet Kit Ø80-125 code CGAS000231.
The
maximum vertical length
counted from the boiler, including the kit end, is 7 metres (EV 30 HFC)
and 10 metres (EV 20 HFC). Each elbow of 90°, or two of 45°, reduces the available length by 1 metre.
Vertically outlet
80/125
inox Cód. CGAS000181
Vertically outlet
80/125
PP Cód. CGAS000360
Black tile
80/125
Cód. CGAS000074
45º elbow
80/125 inox Cód. CGAS000183
45º elbow
80/125 PP Cód. CGAS000081
90º elbow
80/125 inox Cód. CGAS000182
90º elbow
80/125 PP Cód. CGAS000080
1m coaxial duct
80/125
inox Cód. CGAS000184
1m coaxial duct
80/125 PP
Cód. CGAS000082
Black tile
80/125
Cód. CGAS000075
Examples of installation:
L
10 mts. (EV 20 HFC)
L
7 mts. (EV 30 HFC)