Note: The Ceiling Fan must be installed by a licensed Electrician. Ensure the power is switched off before fitting this ceiling fan. 

For any questions, please call Domus® on (02) 9554 9600, Monday to Friday 9am – 5pm EST.

Step 6

• 

Assemble the blade holders to the blades using the nuts, washers and bolts.

• 

Attach the blade holders to the fans with screws and spring washers provided.

• 

If more than one fan is being installed at the same time, be careful not to mix the blades as each set is weight 

matched and balanced to the fan.

• 

Mixing the blades will cause the fan to wobble and this is not covered under warranty.

• 

Screw the decorative plate into the threaded hole on the bottom of the fan (if the light is not used and if it is not 

already attached).

NOTE:

 To reduce the risk of injury, do NOT bend the blade holder during installation, balancing or cleaning of the 

blades. Do not insert foreign objects on or between rotating fan blades.

Step 7  - Installing light bulbs (fans with light kits only)

• 

Remove the lamp Shade  glass carefully. Gently pull down the glass shade as it is held on by spring clips.

• 

Insert the CFL bulb (1x15W “MAX”) in the holder. Always use a pair of gloves or keep your hands clean when 

installing or replacing CFL bulbs.

• 

LED lamps are also permitted.

• 

Replace the glass by bringing the spring clips inwards as you position the glass back into place

• 

Please ensure all the clips are inside the glass to stop the glass from possibly falling.

NOTE:

 Ensure the power is switched off before fitting the bulbs.

Содержание Viento-48

Страница 1: ...CED ELECTRICIAN TO PROTECT THE SAFETY OF OUR SERVICE AGENTS WARRANTY WILL BE VOID IF INSTALLER DETAILS ARE NOT AVAILABLE FOR CONFIRMATION 29 31 Richland St Kingsgrove Sydney NSW 2208 Australia Phone 0...

Страница 2: ...IENTO 48 B 48 Blade Brushed Aluminium Finish Ceiling Fan 50082 VIENTO 48 W 1xE27 48 Blade Satin White Finish Ceiling Fan with light 50083 VIENTO 48 B 1xE27 48 Blade Brushed Aluminium Finish Ceiling Fa...

Страница 3: ...the ceiling material NOTES If installing on raked ceiling make sure the lug in the mounting bracket is on the high side towards the highest point of the roof If lug is on the low side the fan will no...

Страница 4: ...ts Mounting Bracket Blue Brown Green Yellow Ceiling Note The Ceiling Fan must be installed by a licensed Electrician Ensure the power is switched off before fitting this ceiling fan For any questions...

Страница 5: ...is is not covered under warranty Screw the decorative plate into the threaded hole on the bottom of the fan if the light is not used and if it is not already attached NOTE To reduce the risk of injury...

Страница 6: ...Blades will spin clockwise when viewing from underneath Note The Ceiling Fan must be installed by a licensed Electrician Ensure the power is switched off before fitting this ceiling fan For any quest...

Страница 7: ...or cut leads shorter 7 Do not drop or bump the unit 8 PLEASE NOTE The battery will weaken with age and should be replaced before leaking takes place as this will damage the transmitter 9 The batterie...

Страница 8: ...Light Live BLUE Fan Neutral 1 For fans that are not drop rod styles i e Flush Mount Styles the appropriate conversion kit should be used The fan should be installed and hanging from the ceiling It ha...

Страница 9: ...locked into place with the lug in the mounting bracket Check that all the blades are screwed firmly into the blade holders Make sure that the canopy and the mounting bracket are tightened securely to...

Страница 10: ...under Warranty Signals ripple effect through the mains to signal off peak devices by the electricity supplier may cause noise or flickering of the light kit momentarily at certain times This is not d...

Страница 11: ...r commercial usage the Warranty will be a 1 Year On Site Warranty 9 Signals ripple effect through the mains to signal off peak devices by the electricity supplier may cause noise or flickering of the...

Страница 12: ...reason without notice 22 Domus reserves the right to amend this Warranty Terms Conditions at any time without notice Amended Terms and Conditions will be available from Domus upon request 23 Steel bea...

Страница 13: ...Control units and receivers are backed by a 12 month IN HOME Warranty excluding batteries Details can be found in our Warranty Terms and Conditions located on our website or attached to the back of th...

Страница 14: ...________________________________________________ _______________ Purchase Details Place of Purchase _________________________________________________________________________ Date of Purchase _________...

Страница 15: ...ny replacement parts or products if any in addition to the costs associated to ship these parts to my location may incur additional costs This will be assessed upon arrival by the authorised Domus Ser...

Страница 16: ...29 31 Richland St Kingsgrove Sydney NSW 2208 Australia Phone 02 9554 9600 Fax 02 9554 9433 sales domuslighting com www domuslighting com...

Отзывы: