background image

17

Dominator Select 

Instruction Manual

Symptom

Possible cause

Remedy

The opener does 

not work from the 

transmitter

Garage door in poor condition e.g. 

springs may be broken
The opener does not have power

The battery in the transmitter is flat 

 

The opener has turned on 

“Vacation Mode” 

 

The transmitter button is not 

programmed to operate the door.

Check the door’s operation  

Plug a device of similar voltage (e.g. a hairdryer) 

into the power point and check that it is OK
Replace the battery 

 

Turn off “Vacation Mode”  

(Section 15) 

Code in the transmitter 

One transmitter works 

but the other/s do not

Faulty transmitter

Flat battery

Replace transmitter

 

Replace battery

The chain / belt moves 

but the door remains 

stationary

The opener is disengaged

Re-engage the opener  

Motor is running but 

chain / belt is not 

moving

Damage motor assembly

Contact your dealer for support.

The transmitter range 

varies or is restricted

Variations are normal depending 

on conditions e.g. temperature or 

external interference
The battery life is exhausted 

Position of the transmitter in the 

motor vehicle

Make sure you can see the door when you use 

the transmitter.

Check the battery status by pressing a button 

(flashing or no light, battery need changing)
Aim the transmitter through the windscreen.

The Courtesy light does 

not work

LED has failed

Change LED.

The door reverses for no 

apparent reason

This may occur occasionally from 

environmental conditions such as 

areas that are windy, dusty or have 

extreme temperature changes.  
If Safety beams are installed they 

may be partially obstructed.

Ensure the door runs smoothly before increasing 

the force pressure.
 

 

Ensure the beam path is not obstructed. Check 

the Alignment.

Door will not close

Safety Beam not working

Safety Beam battery flat

To access safety close mode, hold the transmitter 

button to close for 6 seconds and continue to 

hold while the door closes.

Check Safety Beam

Auto Close not working

Safety Beam or wiring faulty

Repair Safety Beam or replace wiring.

Re-align optics. See Safety Beam instructions.

The CLOSE (Blue) LED is 

flashing

Limits are not set

Set Up Limits (Section 12).

20. Troubleshooting

If You Need a Service Call

If the opener needs a service please call the dealer who installed the garage door opener (their contact details are 

usually on a sticker on the back of your garage door). For product assistance contact 0800 366 462 within New Zealand

BEFORE CALLING

 you should have the following information to assist in providing the appropriate 

service:

1.  Has anything happened since the opener last operated OK, e.g. a storm, a jolt to the door etc.?

2.  What is the current light status on the opener? 

3.  Manually disengage the door (Section 17).  

How easy is it to manually open and close the door?

4.  What model is the opener? (Model no. information is located at the rear of the opener)

5.  Who installed the opener? (Dealer details should be on a sticker on the back of your garage door)

6.  When was it installed? (If known)

Flashes Issue

Remedy

2

PE is preventing door from moving

Clear away any obstructions. Test Door. If unable to move 

the door and suspect beam is faulty, enter Safety Beam 

Emergency Close by pressing and holding a pre-coded 

button on transmitter for more than five seconds and the 

door will start closing.

3

Wireless LOCK battery is low

Change LOCK battery

Wireless PE battery is low

Change PE Battery

5

Wireless LOCK is not unlocked and preventing door 

moving

Check LOCK, test by pressing emergency release button on 

the lock and then test door operation.

Maintenance is due after pre-set number of cycles. 

Contact dealer to arrange service.

7

Standby battery is faulty

Contact 0800 366 462 within New Zealand for assistance 

Door was obstructed

Clear away any obstructions and test door opens/

closes correctly. (If door is damaged, contact your door 

professional)

Motor overloaded or stalled

Check the doors operation by disengaging the motor and 

ensuring the door runs smoothly. If necessary make door 

adjustments or contact your door professional.

Main Light = Service / Warning Indicator:

Requirements for a service and user warnings are indicated after operation by the main light repeatable 

flasing OFF a number of times followed by a pause. The below table identifys the issues and remedies.

Содержание Select DSO-1

Страница 1: ...ese instructions are intended for professional garage door installers All references are taken from inside looking out Select Doc 160407_00 Part 87186 Released 12 11 19 Sectional Door Opener Select DSO 1 ...

Страница 2: ...e position 21 F Setting up Tilt Door 22 23 Warranty 23 Home Owner Instructions WARNING IMPORTANT SAFETY INSTRUCTIONS FOLLOW ALL INSTRUCTIONS SINCE INCORRECT INSTALLATION CAN LEAD TO SEVERE INJURY before installing the drive remove all unnecessary ropes or chains and disable any equipment such as locks not needed for powered operation before installing the drive check that the door is in good mecha...

Страница 3: ...s Practice correct lifiting techniques when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact while on ladder Crush injury from unsecured door Place a 2 metre exclusion zone around area under the door while i...

Страница 4: ...m force required to move the door should not exceed 20kg d Lift the door to about halfway When released the door should stay in place 2 1 Examine the conditions in the garage a Look at the ceiling i Is it plastered The opener is mounted to a perforated angle which MUST be securely fastened to a structural support You will need to locate the structural beams in the ceiling which are generally 400mm...

Страница 5: ... x Track Bracket 16 1 x Pre Assembled track 5 Position The Opener a MUST BE installed in a dry position protected from weather b REQUIRES properly earthed 3 pin single phase power on the ceiling within an arms length of the opener c Requires a MINIMUM HEADROOM of 57mm between the highest point of the door s travel and the ceiling d Use the diagram below as a reference when completing the installat...

Страница 6: ...O NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profressional for installation DIY c Using step ladder and a level transfer this height to the wall above the door and mark a line 60mm above it across the centre line 7 2 Mounting the Wall Bracket a Draw two lines extending 21 5mm from each side of the centre point b Centre the wall bracket 6 over the intersecti...

Страница 7: ... the door requires 2 x perforated L shape metal strips and 2 x shorter perforate L shape metal drop down strips Not supplied 9 Mounting Brackets and Arms 9 1 Mounting the Door Bracket a The door bracket locator 7 is placed over the door bracket 8 on the door s centre line one third down the top panel and mounted using M6 or equivalent screws not supplied b STEEL DOORS ONLY Bracket can be welded in...

Страница 8: ...range 230V 240Va c Rated frequency 50Hz 60Hz Rated power input 165W Door opening Maximum Door Area Maximum Door Weight Door must be well balanced and able to be operated by hand as per warranty conditions and AS NZS 4505 2012 15m2 140kg Minimum headroom 57mm Rated Operating Time 4 mins Rated Temp 5 o C to 40 o C Short Term Peak force 700N Door travel speed mm sec 140mm Rated load 400N Nominal forc...

Страница 9: ... button on the opener it will cycle through all three speed modes as shown in table iii Once at the desired speed release the CLOSE button iv To set the close limit inch the door by making single presses of the CLOSE button to the desired position We recommend the CLOSE limit position being the first point of contact of the rubber strip at the bottom of the door with the ground v If the door overs...

Страница 10: ...oor does not reverse readily when closing or stop when opening put the door into manual by pulling down on the manual release string to diesengage the motor and contact 13 62 63 for support 13 3 Test the Manual Door Operation Periodically disengage the opener and manually operate the door The door must be smooth to operate by hand The force required on the bottom rail should not exceed 20kg CAUTIO...

Страница 11: ...n this mode the timer starts counting down only when the safety beam is triggered ie car leaving the garage To enable the Auto Close function a Press the MODE button repetitively until the GEAR LED starts flashing b Press the OPEN button until the GEAR LED flashes i two 2 times to get to PE auto close or ii three 3 times to get to standard auto close c Press STOP SET button to enter parameter d Th...

Страница 12: ...nstallation of the Wall Mounted Transmitter a Store the transmitter code as per instructions above Test the transmitter button b Mount the transmitter in a convenient location yet out of reach of children and at least 1 5m off the ground c Make sure the door is visible from this location 15 5 Remotely Coding Transmitters Using this method transmitters can be coded without access to the opener s co...

Страница 13: ...age door balanced Sticking or binding doors must be repaired Garage doors door springs brackets and their hardware are under extreme tension and can cause serious personal injury DO NOT attempt any garage door adjustment DO NOT use if repair or adjustment is needed Call for a professional garage door service CAUTION Emergency access If your garage has no pedestrian entrance door an emergency acces...

Страница 14: ...med transmitter button until your door begins to move usually 2 seconds Make sure you can see the door when you use the transmitter b If you are in a vehicle you should aim the transmitter through your windscreen as shown c Check that the door is fully open or closed before you drive in or away d If you press the transmitter whilst the door is moving the door will stop The next press of the transm...

Страница 15: ...ROW Green Opens the door 5 UP ARROW LED Green Illuminates when the door is open and flashes when the door is open with the auto close timer running obstructed on opening or stopped 6 MODE Yellow Enables Load Diagnostics Mode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 REMOTE CONTROL STATUS LED Red Flashes on remote lockout and flickers on remote control activity 9 ADJUSTMENT LE...

Страница 16: ...nditions e g temperature or external interference The battery life is exhausted Position of the transmitter in the motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashing or no light battery need changing Aim the transmitter through the windscreen The Courtesy light does not work LED has failed Change LED The door reverses fo...

Страница 17: ...o move the door and suspect beam is faulty enter Safety Beam Emergency Close by pressing and holding a pre coded button on transmitter for more than five seconds and the door will start closing 3 Wireless LOCK battery is low Change LOCK battery 4 Wireless PE battery is low Change PE Battery 5 Wireless LOCK is not unlocked and preventing door moving Check LOCK test by pressing emergency release but...

Страница 18: ...erminals must be securely insulated with a non conductive material to prevent any two batteries from short circuiting and generating heat during storage or transport Battery terminals may be insulated with electrical tape or batteries may be individually packaged in a non conductive material e g plastic bag or original packaging 21 3 Battery Disposal Battery Type 3V Lithium Battery CR2032 To test ...

Страница 19: ...utoclose timer running Opening Obstructed on Open Closed Closing Obstructed on Close Stopped Partial Open MODE LED 3 flashing Load Diagnostics mode BATTERY LED 4 off solid flashing rapid flashing Battery not used not fitted Battery charged Battery charging when connected to power without power battery in use holding STOP for 10s will shutdown Battery failed REMOTE CONTROL STATUS LED 5 flashing rap...

Страница 20: ... change accordingly e Press STOP SET button to save the parameter s new value or press MODE to leave the value unchanged f Continue from a above to select another parameter or press MODE to exit adjustment mode The Safety Obstruction Force is calculated automatically during setup Adjusting this is normally only necessitated by environmental conditions such as windy or dusty areas and areas with ex...

Страница 21: ...mote to move the door in the OPEN direction vi When the door is at the desired CLOSE position press the SET button 2 the GREEN LED on the OPEN button will now flash Button 1 inch Open Button 2 Set Button 4 inch Close OPEN limit i Using the programmed transmitter press and hold the button 1 to open To inch the door single presses of the button 1 will move the door to desired limit ii While inching ...

Страница 22: ...on repetitively until the GEAR LED starts flashing b Press and hold STOP SET button for 2 seconds to check the door type until the main courtesy light turns solid ON or OFF Main courtesy light ON Tilt type J Type only Main courtesy light OFF Sectional type c Press and hold STOP SET for 6 seconds to change the door type until the main courtesy light turns solid ON or OFF If required repeat step b t...

Страница 23: ...CAD Smart 7 yrs 20 000 cycles 236kg CAD Secure 7 yrs 20 000 cycles 236kg CAD S 7 yrs 20 000 cycles 175kg Select 5 yrs 10 000 cycles 140kg Panel Pro 5 yrs 10 000 cycles 110kg ROLLING CAD PowerDrive 7 yrs 20 000 cycles 110kg EXTRAS TRACK ASSEMBLY includes all parts 1 year TRANSMITTERS ACCESSORIES 1 year 3 WARRANTY EXCLUSIONS This warranty excludes defects or improper operation resulting from a exces...

Страница 24: ...Hornby Christchurch New Zealand Dominator Locations Nationwide PH 0800 DOMINATOR 366 462 or visit dominator co nz dealer locations dominator co nz Prefixed trademarks are the property of B D Door NZ Ltd Dominator Garage Doors Openers is a division of B D Group Pty Ltd ABN 25 010 473 971 2019 B D Group Pty Ltd ...

Отзывы: