background image

EN

Operation

CF18 – CF60

14

Turning the lid around (CF50, CF60)

You can turn the lid around if you want to open the lid from the other side. To do this, 
proceed as follows:

Open the lid and pull it out (

A

).

Turn the lid.

Insert the lid in the lid holders on the opposite side of the cooler (

B

).

Selecting the temperature units (CF25, CF35, CF40, CF50, CF60)

You can switch the temperature display between Celsius and Fahrenheit. This is how 
to do it:

Switch on the cooler.

Press the “SET” button (fig.

4

4, page 10) twice.

Use the “UP +” (fig.

4

6, page 10) and “DOWN –” (fig.

4

7, page 10) buttons 

to select Celsius or Fahrenheit.

The selected temperature units then appear in the display for a few seconds. The 
display flashes several times before it returns to the current temperature.

A

B

CF 50,  CF 60

8

CF18-CF60-O-AUS.book  Seite 14  Dienstag, 17. September 2019  8:49 08

Содержание WAECO CF18

Страница 1: ...CF18 CF25 CF35 CF40 CF50 CF60 Compressor Fridge Freezer Operating manual EN MOBILE COOLING CF CF18 CF60 O AUS book Seite 1 Dienstag 17 September 2019 8 49 08...

Страница 2: ...ation of symbols 2 2 Safety instructions 3 3 Scope of delivery 6 4 Accessories 7 5 Intended use 7 6 Function description 8 7 Operation 12 8 Cleaning and maintenance 22 9 Guarantee 23 10 Troubleshootin...

Страница 3: ...aged it must be replaced by the manufacturer customer service or a similarly qualified person in order to prevent safety hazards This device may only be repaired by qualified personnel Improper repair...

Страница 4: ...connect the device as follows With the DC cable to a DC plug socket in the vehicle e g cigarette lighter Or with the AC connection cable to the AC mains supply Never pull the plug out of the socket by...

Страница 5: ...as ovens etc Danger of overheating Ensure at all times that there is sufficient ventilation so that the heat that arises during operation does not build up Make sure that the device is sufficiently fa...

Страница 6: ...onnection cable for AC connection 4 2 Only CF35 CF40 CF50 CF60 Carrying handle consisting of 2 holders 1 handle 4 fastening screws 1 Only CF18 Plastic grille divider 1 Only CF35 Powdercoated steel eva...

Страница 7: ...r accessory The cooling device is suitable for camping use and in mobile applications such as vehicles caravans or boats Thecoolingdeviceisintendedtobeusedinhouseholdandsimilarapplicationssuch as staf...

Страница 8: ...CF50 CF60 The cooler can withstand a short term inclination of 30 for example on boats 6 1 Scope of functions CF18 CF25 CF35 CF40 CF50 CF60 Power supply with priority circuit for connecting to the pow...

Страница 9: ...ction description 9 6 2 Operating and display elements Latch for lid Operating panel and DC power supply inlet CF18 1 CF25 CF35 CF40 2 CF18 1 2 3 4 5 3 CF18 CF60 O AUS book Seite 9 Dienstag 17 Septemb...

Страница 10: ...eration LED lights up yellow Set temperature has been reached 3 ERROR LED flashes red Device is switched on but not ready for operation 4 BATTERY MONITOR Switch on device battery monitor 0 Device is s...

Страница 11: ...lay switched off automatically due to low battery voltage 3 ERROR LED flashes red Device is switched on but not ready for operation 4 SET Selects the input mode Temperature setting Celsius or Fahrenhe...

Страница 12: ...ion 1 AC voltage supply inlet 2 Fuse holder 3 DC voltage supply inlet 4 Emergency switch NOTE Before starting your new cooler for the first time you should clean it inside and outside with a damp clot...

Страница 13: ...mbled If you wish to attach the handles proceed as follows Make a handle by putting two holders 1 and a handle 2 together Fasten the grip with the enclosed screws in the holes provided 1 2 1 CF35 CF40...

Страница 14: ...s CF25 CF35 CF40 CF50 CF60 You can switch the temperature display between Celsius and Fahrenheit This is how to do it Switch on the cooler Press the SET button fig 4 4 page 10 twice Use the UP fig 4 6...

Страница 15: ...s equipped with an electronic system to prevent polarityreversal Thisprotectsthecooleragainstshort circuitingwhenconnectingto a battery Using the fused DC plug A Plug the DC connection cable fig 1 2 p...

Страница 16: ...sive discharging when the device is connected to an on board DC supply Ifthecooleris operated when the vehicleignition is switched off thecoolerswitches off automatically as soon as the supply voltage...

Страница 17: ...ay for a few seconds The display flashes several times before it returns to the current temperature I CF18 CF25 CF35 CF40 CF50 CF60 Battery monitor mode LOW HIGH LOW MED HIGH Switch off voltage at 12...

Страница 18: ...CF40 CF50 CF60 Press the ON OFF button fig 4 1 page 10 for between one and two seconds The POWER LED lights up The display fig 4 5 page 10 switches on and shows the current temperature NOTICE Danger...

Страница 19: ...and then the current temperature is displayed again 7 7 Using the Emergency Switch Theemergency override switch fig 5 2 page 11and fig 6 4 page 11 islocated in the connection panel For normal operati...

Страница 20: ...thecoolingdeviceorontheevaporator This reduces the cooling capacity Defrost the device in good time to avoid this A To defrost the cooler proceed as follows Remove the contents If necessary place them...

Страница 21: ...per half of the housing 1 Carefully raise the upper half of the housing from the lower 6 half Take out the contact pin 3 Replace the defective fuse 2 with a new fuse of the same type and rating 8 A 32...

Страница 22: ...that the air inlet and outlet vents on the device are free of any dust and dirt so that heat can be released and the device is not damaged NOTE The LEDs in the light bulb must be facing the transpare...

Страница 23: ...before power will be supplied to the DC power outlet No voltage present in the AC voltage outlet Try using another plug outlet The device fuse is defective Replace the device fuse see chapter Replacin...

Страница 24: ...not been assembled correctly The fuse of the DC plug has blown Replace the fuse in the DC plug see chapter Replacing the DC plug fuse on page 21 The DC fuse inside the device has blown This can only...

Страница 25: ...ross volume 18 l 25 l Storage volume 18 l 23 l Climate class N or T Ambient temperature 18 C to 43 C 50 F to 109 4 F Noise emission Refrigerant quantity 38 g 40 g CO2 equivalent 0 054 t 0 057 t Global...

Страница 26: ...class N or T Ambient temperature 18 C to 43 C 50 F to 109 4 F Noise emission 45 dB A Refrigerant quantity 40 g 45 g CO2 equivalent 0 057 t 0 0064 t Global warming potential GWP 1430 Dimensions W x H...

Страница 27: ...mate class N or T Ambient temperature 18 C to 43 C 64 4 F to 109 4 F Noise emission 45 dB A Refrigerant quantity 45 g 55 g CO2 equivalent 0 064 t 0 079 t Global warming potential GWP 1430 1430 Dimensi...

Страница 28: ...0 0 s YOUR LOCAL DEALER dometic com dealer YOUR LOCAL SUPPORT dometic com contact dometic com 1 01 1 0 4 0 1 1 2 2 1 2 9 0 DOMETIC GROUP AB 3E 0 1 4 4445102487 09 2019 CF18 CF60 O AUS book Seite 28 Di...