9. Customer service
Before notifying customer service, please check the
following:
Are location and ventilation satisfactory?
Is the appliance level?
Is there a current in the wall socket and is the
connection suitable for the appliance?
Is the mains power cable damaged?
For mains operation, is the electric thermostat swiched
on?
For gas operation, was the safety valve knob pressed
down long enough?
Is the thermostat knob set towards the maximum
position?
Is the gas cylinder or the pressure regulator valve open?
Is there any gas in the cylinder? (If by shaking, no liquid
movement can be detected, then the cylinder is empty.)
Are by any chance two different power sources
connected (such as gas or electricity)?
Was warm food placed in the unit?
Was a large quantity of food put in at one time?
If after checking the above, the appliance still does not
operate properly, contact customer service.
When reporting the problem, state the type of problem, the
type of appliance, and the product number and serial
number from the data plate.
We assume the warranty in accordance with our warranty
assumptions for the appliance.
www.dometic.com
10. Putting into operation
You must, in all instances, operate the
appliance from a single energy source only.
Connecting several energy sources at the same time
will cause failure of the appliance.
Technical data:
10.1. Connecting to electrical mains
Make sure no other energy source is connected (gas,
12V).
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to a
mains socket earthed in accordance with regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
data plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted. In the
event of having to change the fuse in the plug supplied,
a 3 amp ASTA approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any reason, the
wires in the mains lead are coloured in accordance with
the following code:
Green and Yellow:
Earth
Blue:
Neutral
Brown:
Live
The wire coloured green and yellow must be connected
to the terminal marked with the letter „E“ or by the earth
symbol
or coloured green and yellow.
The wire coloured blue must be connected to the
terminal „N“ or coloured black.
The wire coloured brown must be connected to the
terminal marked „L“ or coloured red.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
Model
RC 1200 EGP
RC 1600 EGP
RC 1700 EGP
RC 2200 EGP
Type
JCB - 1
JCB - 1
Gross volume
41 litre
33 litre
Mains operation
220 - 240V (AC)
220 - 240V (AC)
Input
85W
75W
Energy consumption
1.38 kWh/24h
1.35 kWh/24h
Battery operation
12V (DC)
12V (DC)
24V (DC)
Input
85W
75W
65W
Energy consumption
170Ah/24h
150Ah/24h
65Ah/24h
Gas pressure (p)
28-30/37 mbar
28-30/37 mbar
Gas classification
I
3
+
I
3
+
Jet size
2
2
Rated thermal loading: butane 134W - 9,8 g/h
134W - 9,8 g/h
(propane)
(118W - 8,4g/h)
(118W - 8,4g/h)
Min.thermal loading: butane 106W - 7,7g/h
106W - 7,7g/h
(propane)
(86W - 6,1g/h)
(86W - 6,1g/h)
Climate class
N
N
Refrigerant
143g H
2
O + 67g NH
3
143g H
2
O + 67g NH
3