EN
Operating the generator
TEC29EV
18
RESTART GEN?
Message appears after the
generator has stopped due to
overheating.
The generator is switched off. Press the start button to
restart the generator.
GEN CAL
Message appears when the
generator is started up; it
shows the calibration phase
which takes place before
each start-up. The generator
does not supply any voltage.
The generator is running but
does not supply any voltage.
Wait a moment.
GEN WAIT
Message appears while you
are waiting for the generator
to start again.
The generator is switched off. Wait until the message has
disappeared then attempt
ignition again.
GEN ON
The generator is operating
normally.
Normal mode
–
GEN OFF
The generator is in stand-by
and can be started.
–
AUTO?
Message appears when the
automatic mode is switched
on.
Controls are waiting for user
input
Press the start button within
20 seconds and hold down
for 5 seconds.
AUTO
Automatic mode
The automatic mode is
switched on
–
Display message
Description
Generator behaviour
Measures