EN
TEC29 EV, TEC 29 EV LPG
Operating the generator
17
Displays
8
Operating the generator
A
I
8.1
Basic notes on operation
!
Please note the following basic information:
•
Always check the oil level before use (chapter “Checking the oil level” on
page 21).
•
TEC29 EV LPG only:
Check there are no leaks from the gas supply using a leak
detection spray before every use.
•
Even small overloads in the long-run will cause the cut-out switch (
TEC 29 EV
) or
the fuses (
TEC29 EV LPG
) to trigger.
No. in
fig.
3
,
page 4
Description
6
AC supply
Actual voltage output
7
Constant output
Current capacity of connected consumer
8
Operating hours
Time the generator is in operation
9
DC voltage
Battery voltage
10
Messages
Status reports of the generator (see chapter
“Display messages” on page 19)
NOTICE!
Do not run the generator over 70 % of the maximum constant output for
the first 50 operating hours (run-in phase).
NOTE
Run the generator at a maximum of approx. 75 % of the maximum
continuous load after the run-in phase.
By doing this you can prolong the service life of the generator and
maximise its efficiency.
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the intake
grille.
TEC29EV-TEC29EVLPG--O-16s.book Seite 17 Mittwoch, 3. Mai 2017 4:45 16
Содержание TEC29
Страница 2: ...TEC29EV TEC29EVLPG O 16s book Seite 2 Mittwoch 3 Mai 2017 4 45 16 ...
Страница 8: ...TEC29 EV TEC29 EV LPG 8 0 TEC29EV TEC29EVLPG O 16s book Seite 8 Mittwoch 3 Mai 2017 4 45 16 ...
Страница 9: ...TEC29 EV TEC29 EV LPG 9 a TEC29EV TEC29EVLPG O 16s book Seite 9 Mittwoch 3 Mai 2017 4 45 16 ...