27
Refrigerator operation
Operation with batteries (internal power supply)
Indicator
Fault
Remedy
flashing
brightly l
Check burner, burner nozzles, if necessary contact
Customer Service and arrange replacement
Burner defective or coo-
ling unit defective
7
3
Automatic switching
from external to internal
power supply does not
function
(absence of the on-
board 12 V power sup-
ply for the electronics)
Switch off the refrigerator and start again.
The on-board power supply was interrupted during
the starting of the gas operation.
Note:
No automatic switching is performed during
the ignition.
Refrigerator does not
function;
gas operation not possi-
ble although the batte-
ries are inserted.
flashing
brightly
Flame not ignited
8
3
Check gas supply (gas bottle, gas valve)
Press the button after clearing the fault.
Acoustic signal at 15
second intervals
Undervoltage detection
(internal batteries)
Replace batteries
Содержание RMD 8501
Страница 57: ...www dometic com...