background image

6

Safety instructions

2.0 Safety instructions

This refrigerator is designed for installation in
recreation vehicles such as caravans or
motorhomes. The appliance has been type-
approval tested for this application in accor-
dance with the EC Gas Directive.

The refrigerator is to be used solely for storing
foodstuffs.

2.1

Application according to 
regulations

2.3

Working upon and checking 
the refrigerator

Work on gas equipment, exhaust system
and electrical facilities must be carried
out by authorised personnel only.
Substantial damage to property and/or
injury to persons can arise through unpro-
fessional procedures.

WARNING! 

Never use an unshielded flame to check
gas bearing parts and pipes for leakage!

There is a danger of fire or explosion.

DANGER! 

Never open the absorber cooling unit! It is
under high pressure.

There is a danger of injury!

WARNING! 

Anyone operating the refrigerator must be
familiar with the safe handling and understand
the advice in the operating instructions (part
no.  821 2690-94). 

2.2

User's responsibility

It is imperative that the operating pressure
corresponds to the data specified on the
rating plate of the appliance. Compare the
operating pressure of the rating plate with the
data specified on the pressure reducing valve
of the liquid gas cylinder.

2.4

Operating the refrigerator 
with gas

The refrigerator must not be exposed to
rain.

CAUTION!  

Содержание RM 5310

Страница 1: ...Installation instructions Absorption Refrigerator for Recreation Vehicles RM 5310 RM 5330 RM 5380 MBA 11 2011 N 1 Type C40 110 821 2690 99 AUS NZ ...

Страница 2: ...ructions 9 4 1 Installation 9 4 1 1 Side installation 9 4 1 2 Side installation with floor roof ventilation 10 4 1 3 Rear installation 10 4 1 4 Draught proof installation 11 4 2 Ventilation and air extraction of the refrigerator 12 4 3 Installing the ventilation system 13 4 4 Exhaust gas duct and installing the fume flue 14 4 5 Installation recess 15 4 5 1 Installation in the recess 15 4 5 2 Reces...

Страница 3: ...nite from the burner flame CAUSING A FIRE OR AN EXPLOSION FOR YOUR SAFETY it is recommended that all LP gas appliances which are vented to the outside should be shut off when refueling The refrigerator must be shut off during refueling WARNING Lifting carrying the refrigerator Never use for lifting or carrying other parts of the refrigerator i e cooling unit gas pipe frontpanel The refrigerator wi...

Страница 4: ...rmation texts and illustrations in these instructions are copyright protected and are subject to industrial property rights No part of these instructions may be reprodu ced copied or utilised in any other way wit hout written authorisation by Dometic GmbH Siegen 1 3 Copyright protection 1 4 Explanation of symbols used in this manual Warning notices are identified by symbols A supplementary text gi...

Страница 5: ...l of the appliance Warranty arrangements are in accordance with the normal conditions applicable for the country concerned For warranty or other maintenance please contact our customer services department Any damage due to improper use is not covered by the warranty The warranty does not cover any modificati ons to the appliance or the use of non origi nal Dometic parts The warranty does not apply...

Страница 6: ...hrough unpro fessional procedures WARNING Never use an unshielded flame to check gas bearing parts and pipes for leakage There is a danger of fire or explosion DANGER Never open the absorber cooling unit It is under high pressure There is a danger of injury WARNING Anyone operating the refrigerator must be familiar with the safe handling and understand the advice in the operating instructions part...

Страница 7: ... the product number and the serial number You will need these details whenever you contact the customer service centre or when ordering spare parts 3 2 Refrigerator rating plate Model number Product number Serial number Electrical rating details Gas pressure 2 1 3 4 5 RM 5 3 1 0 Refrigerator Mobile Mobile Absorption Refrigerator manual ignition with battery igniter Model variant Model range with b...

Страница 8: ...25 W 120 W 125 W 120 W ca 2 5 KWh 270 g ca 2 5 KWh 270 g ca 2 5 KWh 270 g Model Dimensions Gross capacity Rating details Consumption Net Ignition H x W x D mm freezer mains battery electricity gas weight Piezo Automat Depth incl door compartment over 24hrs 5 lit 5 lit 5 lit Subject to technical changes Average consumption measured at an average ambient temperature of 25 C in pursuance of ISO Stand...

Страница 9: ...tic result in Dometic GmbH s warranty obliga tions becoming void The appliance may be installed by authori sed personnel only WARNING Fig 6 The air vent grilles offer an unobstruc ted dissipation of heat and exhaust gas even when the door is opened 4 1 1 Side installation If the appliance is installed on the same side of the vehicle as the entrance door it is desirable that the door does not cover...

Страница 10: ...N Fig 8 Fig 9 Air vent grille not blocked OK Air vent grille blocked 4 1 3 Draught proof installation Refrigerators in motorhomes caravans or other vehicles must be installed in a draught proof manner This means that the combusti on air for the burner is not taken from the living space and that exhaust fumes are prevented from entering the living space Adequate sealing between the back of the refr...

Страница 11: ...l lation recess from the front Ensure that the seals abut the case evenly This installation option facilitates the removal and installation of the appliance for servicing The cavity in between the outer vehicle wall and refrigerator is completely isolated from the vehicle interior Intrusion of exhaust fumes into the living space is prevented Fumes will esca pe through the upper ventilation grille ...

Страница 12: ... of two apertures in the caravan wall Fresh air enters at the bottom extracts the heat and exits through the upper vent grille chimney effect The upper ventilation grille should be positioned as high as possible above the condenser 1 2 Fig 17 Install the lower ventilation grille at floor level of the recess allowing unburnt gas heavier than air to esca pe directly into the open air The gas burner ...

Страница 13: ...er ventilation grille 4 3 1 Ventilation systems Fig 23 Seal the mounting frame making it waterproof does not apply for mounting frames with integral seal 1 Fig 24 Insert frame and screw into position 2 To install the ventilation grilles LS 200 cut two rectangles 451mm x 156mm in the outer wall of the vehicle for position of the cuts ssee Fig 16 Fig 25 Insert and lock ventilati on grille 3 Fig 26 C...

Страница 14: ...uild up of condensate The type of exhaust gas duct shown in Fig 25 allows the installati on of the winter cover next to A Fig 25 4 4 Exhaust gas duct and instal ling the fume flue An installation other than described will reduce the cooling capacity and jeopardi se the manufacturer s warranty product liability CAUTION Installing the standard fume flue Fig 25 1 Connect T piece E to adaptor F or flu...

Страница 15: ...n 4 1 4 The measurements of the recess are stated in the table below Step A Fig 26 is only requi red for cabinets with a step The floor of the recess must be level allowing the appliance to be pushed easily into its correct position The floor must be substantial enough to bear the weight of the appliance 4 5 Installation recess Installation 4 5 2 Recess dimensions Fig 26 A H T TST HST Height Width...

Страница 16: ...e supplied with the refrigerator 4 6 Securing the refrigerator Always insert screws through the sleeves provided as otherwise components laid in foam such as cables etc could be dama ged CAUTION 4 7 Inserting the decor panel Remove the door Loosen three screws of the lower trim moulding and remove trim moulding Fit new panel and slide it upwards as far as possible Fit the trim moulding back in pla...

Страница 17: ...ce must be installed securely and free of stress using pipe connectors and must be securely connected to the vehicle a hose connection is not permissible The gas connection to the appliance is 1 8 BSP Female s figure 33 The refrigerator must be equipped with a shut off valve allowing to cut the supply line Such a shut off device must be readily accessible to the user Before Leaving Check all conne...

Страница 18: ...r Services or by qualified per sonnel to avoid hazards We recommend leading the power supply via a board side fuse protection 4 9 2 Battery connection The machine s 12V connection cable is con nected observing correct polarity to a termi nal strip The wiring for the heating element refer to A B wiring diagram connections con nection cable white red must be direct and by the shortest possible route...

Страница 19: ...d heating element DC B Positive connection h e DC C Ground interior lighting D Positive connection interior lighting Fig 36 Fig 37 1 1 1 A B A B C D 12V connection appliance without interior lighting mains connections 12V connection appliance with interior lighting ...

Страница 20: ...20 Installation Fig 38 Wiring diagram RM 5xx0 without interior lighting 4 9 4 Wiring diagrams A ground heating element 12VDC B plus heating element 12VDC Connections ...

Страница 21: ...21 Installation Fig 39 Wiring diagram RM 5xx0 with interior light A ground heating element 12VDC B plus heating element 12VDC C ground interior light 12VDC D plus interior light 12VDC Connections ...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...24 www dometic com ...

Отзывы: