Control Parameters
• To use reverse-cycle and auxiliary electric heat,
select On.
• To allow the auxiliary electric heater to operate
at the same time as the reverse-cycle heating
when the dehumidification feature is active
and required, select aux heat. Auxiliary heat
output will also operate when using the
optional seawater low-limit adjustment or the
auto changeover feature, if enabled. See the
seawater low-limit adjustment on page 23.
–
For CW Applications .
Allows an optional
auxiliary electric heater to operate.
• To use electric heat and/or hydronic heat,
select On. Selecting On allows the electric
heater to operate at the same time as the
hydronic valve when the dehumidification
feature is active and required. The compressor
and auxiliary heat spade terminal outputs will
energize when CW electric heat is called for.
• To use only hydronic heat, select Off (default).
I
Please consult with Dometic Customer Service or
with an authorized service technician for assistance.
8 Fan Motor Type .
Use the default split capacitor
setting for air conditioning units with high-velocity
blowers.
I
Only change the setting to shaded pole if the unit
has a shaded pole fan motor, recognizable by a
blower-motor overhang.
I
The split capacitor motor of a high-velocity unit is
inside the blower, and the unit has “VTD” or “HV”
in the model number.
9 Filter Hours
Setting .
Enables a reminder to clean or
replace the air filter. The default setting is off. Select
the number of operating hours until the filter reminder
appears. Parameter choices are between 100 hours
and 2,500 hours. Once set, the timer tracks the total
amount of run hours that the fan accumulates. When
the timer setting is reached, the status icon flashes
briefly until it is cleared. The room temperature
continues to display and the normal system operation
is not affected. To clear and reset the timer, select
general setting > filter hours setting.
I
Dometic recommends checking the air filter at least
every 500 hours of operation.
13
General Settings Screen 4
10 Filter Hours Reset .
Displays the number of filter
reminder hours accumulated since the timer was
started or reset. To clear the reminder, press the CLR
icon. This resets the value to 0 and restarts the timer.
11 CAN-bus Unit ID .
Displays only when the CAN-bus
network capability is available and the Smart Touch
Cabin Control is plugged into a networked control
board with the CAN-bus daughterboard option. If
the Smart Touch Cabin Control is plugged into a
standard control board, this parameter is unavailable
and the icon is grayed out. Each control on the same
CAN-bus network must be assigned a unique Unit ID
(0–255). For example, the control set to 5 responds
to commands with a destination address of 5.
12 CAN-bus Group ID .
Displays only when the CAN-
bus network capability is available, and the Smart
Touch Cabin Control is plugged into a networked
control board with the CAN-bus daughterboard
option. If the Smart Touch Cabin Control is plugged
into a standard control board, this parameter is
unavailable and the icon is grayed out. Assign the
address for the control’s CAN-bus network group
(0–255). This number should be unique and different
from any CAN-bus unit ID. For example, all controls
that are set to 100 will respond to commands with a
destination address of 100 (in addition to responding
to commands that target their individual Unit IDs).