Technical description
MCR7
EN
4
2.2
Error displays
2.3
Status displays
No. in
fig.
1
,
page 2
Description
Meaning
3
OVP
This LED shows that the inverter is switching off due to
overvoltage.
UVP
This LED shows that the inverter is switching off due to low
voltage.
OTP
This LED shows that the inverter is switching off due to
overheating.
This LED switches off when the inverter has cooled down.
OLP
This LED shows that the inverter is switching off due overloading
or short-circuiting.
No. in
fig.
1
,
page 2
Description
Meaning
4
INV
This LED shows that the inverter is in standby mode.
GRID
No function
PWR SAV.
This LED shows whether the inverter's energy saving mode
(standby) is activated.
•
Constant glow:
The energy saving mode is switched on.
•
Flashing:
The inverter is in energy saving mode.
•
Off:
The energy saving mode is switched off.