Страница 1: ...MCA1215 MCA1225 MCA1235 Battery charger Installation and Operating Manual EN ENERGY LIGHTING PERFECTCHARGE MCA1215 1235 IO AU book Seite 1 Donnerstag 13 Oktober 2016 10 37 10...

Страница 2: ...ith it Table of contents 1 Explanation of symbols 3 2 General safety instructions 3 3 Intended use 8 4 Scope of delivery 9 5 Accessories 9 6 Technical description 10 7 Installing the device 14 8 Conne...

Страница 3: ...for purposes other than those described in the operating manual DANGER Safety instruction Failure to observe this instruction will cause fatal or serious injury WARNING Safety instruction Failure to o...

Страница 4: ...t be used if the device itself or the connection cable are visibly damaged If this power cable for this device is damaged it must be replaced by the manufacturer customer service or a similarly qualif...

Страница 5: ...f gas or dust explosion CAUTION Ensure that the device is standing firmly The device must be set up and fastened in such a way that it cannot tip over or fall down A NOTICE Do not expose the device to...

Страница 6: ...ble and the 12 V DC cable in the same duct Do not lay the cable so that it is loose or heavily kinked Fasten the cables securely Do not pull on the cables 2 4 Operating the device safely D DANGER Dang...

Страница 7: ...e and caustic acids Avoid battery fluid coming into contact with your body If your skin does come into contact with battery fluid wash the part of your body in question thoroughly with water If you su...

Страница 8: ...ate power in vehicles or on boats The MCA charger can be used to continuously charge supply or starter batteries This allows the batteries to be charged and to maintain a high charge level 12 V batter...

Страница 9: ...ory not included in scope of delivery Quantity Description 1 Battery charger 2 230 V power cable 3 Installation and operating manual Description Ref no Remote Control MCA RC1 9102500037 Temperature se...

Страница 10: ...r accessory Battery overheating The device can also be integrated into a LIN bus using two connections The cooling system uses fans whose speed depends on the charging power and can be switched off us...

Страница 11: ...s and controls 1 2 3 4 5 AC INPUT DC OUTPUT 1 2 3 4 STATUS TEMP LIN1 LIN2 ESB 1 2 3 4 5 AC INPUT DC OUTPUT 1 2 3 STATUS TEMP LIN1 LIN2 ESB MCA1215 MCA1225 1235 1 2 3 4 9 8 7 5 6 1 2 3 4 5 6 9 8 7 1 MC...

Страница 12: ...connection 3 TENMP LIN1 bus connection 4 CN2 socket for Alarm and Fan 5 Status LED 6 DIP switch 7 Battery terminals 8 Battery terminals 9 Starter battery connection No in fig 2 page 12 Explanation fu...

Страница 13: ...ry has reached this charging level 2 3 4 U0 phase absorption Now the three stage absorption charging process U0 phase begins where the duration depends on the battery The voltage remains constant U0 I...

Страница 14: ...install the device In wet or damp environments In dusty environments In the vicinity of combustible materials In areas where there is a danger of explosions Connection to supply mains is to be in acco...

Страница 15: ...ce in place you will need Machine bolts M4 with washers and self locking nuts or self tapping screws or wood screws Fasten the device as follows Hold the device against the installation location Mark...

Страница 16: ...ction Black negative connection Do not reverse the polarity Reversing the polarity can cause damage to the device Lay the positive cable from the battery charger to the positive terminal of the batter...

Страница 17: ...215 MCA1225 MCA1235 Connecting the device 17 8 2 Charge versions LIN MPC01 MCA HS1 IBS MCA12xx 4 MCA RC1 MCA TS1 MCA HS1 IBS LIN MCA12xx 5 MCA1215 1235 IO AU book Seite 17 Donnerstag 13 Oktober 2016 1...

Страница 18: ...S1 accessory Connect the battery sensor to the TEMP LIN connection The battery sensor transmits the battery temperature and the battery voltage to the charger via the LIN communication port The chargi...

Страница 19: ...f the RJ 11 cable into the socket fig 6 3 page 19 of the MCA RC1 Insert the other end of the RJ 11 cable into the TEMP LIN1 socket on the MCA battery charger NOTE The length of the RJ 11 cable may not...

Страница 20: ...ring diagram 12 V see fig 7 page 20 No in fig 7 page 20 Explanation function 1 MCA charger 2 Consumer 3 PerfectControl MPC01 4 12 V battery sensor IBS 5 12 V battery 6 Fuse 7 Starter battery LIN 2 3 7...

Страница 21: ...ows The pins for the LIN2 bus socket are assigned as follows Pin in fig 8 page 21 Allocation 1 R_VCC 2 GND 3 TEMP 4 BAT 5 LIN BUS DATA I O 6 BAT Pin in fig 8 page 21 Allocation 1 R_VCC 2 BAT 3 NC 4 BA...

Страница 22: ...as follows Pin in fig 9 page 22 Allocation 1 NC Normally Closed normally closed contact 2 NO Normally Open normally open contact 3 COM Common common contact 4 Sleep mode control 5 GND 4 5 bridged Slee...

Страница 23: ...he temperature for these two functions MCA 12xx 20 mV C S3activatesthepowermodewheneitherS1orS2 orboth aresetto Off Inpower mode the short circuit overvoltage and overheating protection are controlled...

Страница 24: ...etic eStore batteries Enabling the control for external devices such as MPC01 does not apply to MCA RC1 Switch 1 Switch 3 Switchover voltage ON OFF 14 4 V OFF OFF 14 7 V Switch 2 Switch 3 Retention vo...

Страница 25: ...g function on page 13 I Switch 1 Switch 2 Switch 3 ON ON ON Switch 4 ON Display Meaning Orange quickly flashing Phase 1 Orange slowly flashing Phase 2 Orange constantly lit Phase 3 Green constantly li...

Страница 26: ...from being switched on Mode Display Meaning Sleep mode activated Orange constantly lit Phase 1 to 5 Sleep mode deactivated Green slowly flashing Phase 1 to 4 Green constantly lit Phase 5 Fault Red con...

Страница 27: ...rheating Improve the ventilation of the battery charger or battery Make sure that no ventilation openings are covered If necessary reduce the ambient temperature Red permanently lit Short circuit or r...

Страница 28: ...e following documents when you send in the device A copy of the receipt with purchasing date A reason for the claim or description of the fault 13 Disposal Place the packaging material in the appropri...

Страница 29: ...0 mV C battery sensor Vibration Test type Frequency range Vibration profile Sweep rate Duration Test axis Sinusodial sweep 10 50 Hz 0 35 mm 1 oct min 30 min per axis Vertical Voltage insulation I P O...

Страница 30: ...29 and IEC60068 2 6 MCA12xx Output side short circuit Current is reduced to 25 of the maximum current Overvoltage 16 V Protection class IP21 Battery charger over temperature 100 C 5 C measured intern...

Страница 31: ...ter battery 1 1 1 ESB charging voltage 13 8 V 13 8 V 13 8 V ESB charging current 2 A 2 A 2 A MCA1215 MCA1225 MCA1235 Ref no 9108400809 9108400810 9108400811 Dimensions L x W x H mm 238x179x63 238x179x...

Страница 32: ...3 Mail customerservices dometic co nz NORWAY Dometic Norway AS ster yveien 46 N 3232 Sandefjord 47 33428450 47 33428459 Mail firmapost dometic no POLAND Dometic Poland Sp z o o Ul Pu awska 435A PL 02...