background image

miniBar

compressor

RHC 460

RHC 860AC

MBC 600A

Type HC20/60
822 6100-35

ENGLISH

INSTRUCTIONS for USE

INSTALLATION INSTRUCTIONS

T.D. 03/2003

SERVICE OFFICE
The Dometic Corp.
509 So. Poplar St.
La Grange, IN 46761
Phone: 219 463 4858

Sales Office
Intercon Marketing
1540 Northgate Blvd.
Sarasotu, Fl 34234
Phone: 941-355-4488

FOR SERVICE CENTER
ASSISTANCE
CALL: 800 544 4881

WARNING

Improper installation, adjustment, alteration, service or mainten-
ance can cause injury or property damage. Refer to this manual.
For assistance or additional information consult a qualified
installer or service agency .

IMPORTANT INSTRUCTIONS

READ CAREFULLY

RECORD THIS INFORMATION FOR FUTURE REFERENCE
BEFORE INSTALLING THE UNIT:
Model No.

Serial No.

Product No.
Date Purchased

Place of Purchase

9801370

Содержание MBC 600A

Страница 1: ...otu Fl 34234 Phone 941 355 4488 FOR SERVICE CENTER ASSISTANCE CALL 800 544 4881 WARNING Improper installation adjustment alteration service or mainten ance can cause injury or property damage Refer to...

Страница 2: ...7 Electricity Supply 4 7 Securing 5 4 8 Installation 6 4 9 Changing the Sliding Hinge 7 4 10 Changing the Doorhang 8 5 0 INSTRUCTION for USE 9 5 1 Initial Operation 9 5 2 Temperature Control 9 5 3 In...

Страница 3: ...s The miniBar must be installed in such a way that accidental contact with the cooling unit which heats up when in use is impossible The appliance has to be connected to a properly earthed socket in l...

Страница 4: ...onds to the mains voltage Depending on the model the following parts can be found in the miniBar Cleaning Before operating the miniBar we recommend you clean it both inside and outside Use a soft clot...

Страница 5: ...laced by the Customer Service at Dometic or by respectively qualified personnel in order to pre vent any hazards Securing 4 5 1 Tighten the screws 2 Afix the cap 4 6 4 7 The miniBar must be screwed on...

Страница 6: ...measure 105mm x the width of the refrigerator 5 Only the entire cooling unit must project into the duct as shown 6 Air passing through the duct must not be preheated by any source of heat 7 Ventilatio...

Страница 7: ...4 Distance to cupboard door A A 1 When closed the cupboard door A must not lie against the rest of the surrounding cupboard area distance 1 2mm 1 2 1 2 7 mm mm 2 There must be a distance of 6 8mm betw...

Страница 8: ...8 Changing the Doorhang 1 2 3 4 5 6 7 8 9 10 11 R 12 13 R L L 4 10 1 2 1 2...

Страница 9: ...EXCHANGED BY SERVICE PERSONNEL ONLY Initial Operation To obtain spare bulbs please contact your Dometic Service Centre 1 Pull out the mains plug 2 Remove the reflector disk 3 Remove defective LED boa...

Страница 10: ...ing Performance Possible Cause Self Help Authorised Service a The cooling aggregate is not sufficiently ventilated b The fridge door does not close tightly c Light permanently on when door closed d Th...

Страница 11: ...t be disposed of using local collection systems The device itself must be handed over to a disposal company or local council which will guarantee the correct use of recyclable materials and the proper...

Страница 12: ...Dometic GmbH In der Steinwiese 16 D 57074 Siegen GERMANY Tel 49 0 271 692 0 Fax 49 0 271 692 300 www dometic de minibar www dometic com Dometic GmbH 2003 Subject to change without notice...