![Dometic maintenance and Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/dometic/maintenance-and/maintenance-and_operation-maintenance-and-installation-manual_2518723020.webp)
TEC 40D
18
user’s manual
GB
SOLUTION
The emergency stop switch is not to ON
The starter is not powered up
The electrical cables are broken
The generator earth wire (or fuse) is broken
No fuel
Check the load supplied
No fuel received from injectors
The air fi
lter is dirty
The
Air intakes are obstructed
Inverter is damaged
Load over 3.5 kW
Low battery charge
The starter shaft is dirty
Electric pump unfed/out of order
Too much oil in the engine
CAUSE
By operating the main switch, the
panel does not switch on
By pushing the start button, the
generator does not start (the
starting motor does not run)
The starting motor runs but the
generator does not start
The generator tends to stall
The generator runs but it does not
produce current
The generator starts, then stops and
display “generator alert!” message
The produced current oscillates
3.1 Faults, causes and solutions
Operations to be carried
out by the user
Operations to be carried
out by qualified technicians
Troubleshooting, maintenance, recycling